Channel | Description |
ABFR
| Array Induction Quality Control Borehole Formation Ratio |
ACED
| Array Induction Computed Effective Electrical Borehole Diameter |
ACES
| Array Induction Computed Effective Standoff |
ADES
| Array Induction Diagnostic Executive Summary |
ADI07
| AIT Dip Invariant 7 inch Resistivity |
ADI11
| AIT Dip Invariant 11 inch Resistivity |
ADI15
| AIT Dip Invariant 15 inch Resistivity |
ADI22
| AIT Dip Invariant 22 inch Resistivity |
ADI27
| AIT Dip Invariant 27 inch Resistivity |
AE10
| Array Induction Resistivity Environmentally Compensated Log Processing AE10 |
AE20
| Array Induction Resistivity Environmentally Compensated Log Processing AE20 |
AE30
| Array Induction Resistivity Environmentally Compensated Log Processing AE30 |
AE60
| Array Induction Resistivity Environmentally Compensated Log Processing AE60 |
AE90
| Array Induction Resistivity Environmentally Compensated Log Processing AE90 |
AECEF
| Array Induction End Of Casing Effect Flag |
AECF
| Array Induction Environmentally Compensated Log Processing Chart Flag |
AECO10
| Array Induction Conductivity Environmentally Compensated Log Processing AE10 |
AECO20
| Array Induction Conductivity Environmentally Compensated Log Processing AE20 |
AECO30
| Array Induction Conductivity Environmentally Compensated Log Processing AE30 |
AECO60
| Array Induction Conductivity Environmentally Compensated Log Processing AE60 |
AECO90
| Array Induction Conductivity Environmentally Compensated Log Processing AE90 |
AECW
| Array Induction Environmentally Compensated Log Processing Combined Weights |
AEFL
| Array Induction Environmentally Compensated Log Processing Flags |
AEHF
| Array Induction Environmentally Compensated Log Processing Hole Flag |
AEMF
| Array Induction Environmentally Compensated Log Processing Magnetic Mud Flag |
AERS
| Array Induction Environmentally Compensated Log Processing Resolution Flag |
AF10
| Array Induction Four Foot Resistivity A10 |
AF20
| Array Induction Four Foot Resistivity A20 |
AF30
| Array Induction Four Foot Resistivity A30 |
AF60
| Array Induction Four Foot Resistivity A60 |
AF90
| Array Induction Four Foot Resistivity A90 |
AFCB
| Array Induction Four Foot Conductivity Background |
AFCO
| Array Induction Four Foot Conductivity |
AFCO10
| Array Induction Four Foot Conductivity A10 |
AFCO20
| Array Induction Four Foot Conductivity A20 |
AFCO30
| Array Induction Four Foot Conductivity A30 |
AFCO60
| Array Induction Four Foot Conductivity A60 |
AFCO90
| Array Induction Four Foot Conductivity A90 |
AFD1
| Array Induction Four Foot Inner Diameter of Invasion |
AFD2
| Array Induction Four Foot Outer Diameter of Invasion |
AFOO
| Array Induction Four Foot Curves Out of Order Flag |
AFRI
| Array Induction Four Foot Radial Resistivity Image |
AFRT
| Array Induction Four Foot Rt |
AFRWAI
| Array Induction Four Foot Radial RWA Image |
AFRX
| Array Induction Four Foot Rxo |
AFSHI
| Array Induction Four Foot Radial Hydrocarbon Saturation Image |
AFSWI
| Array Induction Four Foot Radial Water Saturation Image |
AFVM
| Array Induction Four Foot Volume Mud Filtrate |
AIBC
| Array Induction Borehole Corrected |
AIBD
| Array Induction Input Borehole Diameter To AIT Processing |
AIEC
| Array Induction Electronically Calibrated |
AIFC
| Array Induction Fully Calibrated |
AIMR
| Array Induction Input Borehole Mud Resistivity To AIT Processing |
AMC
| Array Induction Mud Resistivity Electronically Calibrated |
AMF
| Array Induction Mud Resistivity Fully Calibrated |
AO10
| Array Induction One Foot Resistivity A10 |
AO20
| Array Induction One Foot Resistivity A20 |
AO30
| Array Induction One Foot Resistivity A30 |
AO60
| Array Induction One Foot Resistivity A60 |
AO90
| Array Induction One Foot Resistivity A90 |
AOCB
| Array Induction One Foot Conductivity Background |
AOCO
| Array Induction One Foot Conductivity |
AOCO10
| Array Induction One Foot Conductivity A10 |
AOCO20
| Array Induction One Foot Conductivity A20 |
AOCO30
| Array Induction One Foot Conductivity A30 |
AOCO60
| Array Induction One Foot Conductivity A60 |
AOCO90
| Array Induction One Foot Conductivity A90 |
AOD1
| Array Induction One Foot Inner Diameter of Invasion |
AOD2
| Array Induction One Foot Outer Diameter of Invasion |
AOOO
| Array Induction One Foot Curves Out of Order Flag |
AORI
| Array Induction One Foot Radial Resistivity Image |
AORT
| Array Induction One Foot Rt |
AORWAI
| Array Induction One Foot Radial RWA Image |
AORX
| Array Induction One Foot Rxo |
AOSHI
| Array Induction One Foot Radial Hydrocarbon Saturation Image |
AOSWI
| Array Induction One Foot Radial Water Saturation Image |
AOVM
| Array Induction One Foot Volume Mud Filtrate |
AQABN
| Array Induction Quality Control Borehole Corrected Non-Filtered Array Signal |
AQRI
| Array Induction Quality Control Array Ratio Image |
AQTI
| Array Induction Quality Control Diagnostic Real-Time Image |
ASCA
| Array Induction SP to Armor Calibrated |
AT10
| Array Induction Two Foot Resistivity A10 |
AT20
| Array Induction Two Foot Resistivity A20 |
AT30
| Array Induction Two Foot Resistivity A30 |
AT60
| Array Induction Two Foot Resistivity A60 |
AT90
| Array Induction Two Foot Resistivity A90 |
ATCA
| Array Induction Array Temperature Calibrated |
ATCB
| Array Induction Two Foot Conductivity Background |
ATCE
| Array Induction Cartridge Electronics Temperature |
ATCO
| Array Induction Two Foot Conductivity |
ATCO10
| Array Induction Two Foot Conductivity A10 |
ATCO20
| Array Induction Two Foot Conductivity A20 |
ATCO30
| Array Induction Two Foot Conductivity A30 |
ATCO60
| Array Induction Two Foot Conductivity A60 |
ATCO90
| Array Induction Two Foot Conductivity A90 |
ATD1
| Array Induction Two Foot Inner Diameter of Invasion |
ATD2
| Array Induction Two Foot Outer Diameter of Invasion |
ATOM
| Array Induction Tool Mode |
ATOO
| Array Induction Two Foot Curves Out of Order Flag |
ATRI
| Array Induction Two Foot Radial Resistivity Image |
ATRT
| Array Induction Two Foot Rt |
ATRWAI
| Array Induction Two Foot Radial RWA Image |
ATRX
| Array Induction Two Foot Rxo |
ATSE
| Array Induction Sonde Electronics Temperature |
ATSHI
| Array Induction Two Foot Radial Hydrocarbon Saturation Image |
ATSWI
| Array Induction Two Foot Radial Water Saturation Image |
ATVM
| Array Induction Two Foot Volume Mud Filtrate |
RSP
| Raw SP |
RSPA
| Raw SP Armor To Fish |
SP
| Spontaneous Potential |
SPAR
| SP, Armor Return Compensated |