Parameter | Description |
AGC
| Automatic Gain Control Status |
AMSG
| Auxiliary Minimum Sliding Gate |
BDEP
| Depth of Before Calibration |
BILI
| Bond Index Level for Zone Isolation |
CBAF
| CBL Adjustment Factor |
CBLG
| CBL Gate Width |
CBRA
| CBL LQC Reference Amplitude in Free Pipe |
CDTS
| Correction for Delta-T Shale, Empirical |
CMCF
| CBL Cement Type Compensation Factor |
DDEL
| Digitizing Delay |
DETE
| Delta-T Detection |
DFAD
| Digital First Arrival Detection Switch |
DFAD_TYPE
| DFAD type |
DIVL
| DSLT Depth Sampling Interval |
DRCS
| DSLT DLIS Recording Size |
DSIN
| Digitizer Sample Interval |
DTCM
| Delta-T Computation Mode |
DTF
| Delta-T Fluid |
DTFS
| DSLT Telemetry Frame Size |
DTLI
| Delta-T Limiting |
DTM
| Delta-T Matrix |
DWCO
| Digitizer Word Count |
EDAC
| Error Depth Averaging Constant |
EDTH
| Error Decision Threshold |
FATT
| Acoustic Attenuation due to Fluid |
FCF
| CBL Fluid Compensation Factor |
GAI
| Manual Gain |
GOBO
| Good Bond |
HRSP
| High Resolution Spacing |
ITTS
| Integrated Transit Time Source |
LTUT
| Lower to Upper Transmitter Spacing Ratio |
MAHTR
| Manual High Threshold Reference for first arrival detection |
MATT
| Maximum Attenuation |
MCI
| Minimum Cemented Interval for Isolation |
MGAI
| Maximum Gain |
MIGA
| Minimum Gain |
MNHTR
| Minimum High Threshold Reference for first arrival detection |
MODE
| Sonic Firing Mode (e.g. DDBHC = Depth-Derived BHC, STRA = Single Transmitter, SREV = Single Receiver |
MSA
| Minimum Sonic Amplitude |
NMSG
| Near Minimum Sliding Gate |
NMXG
| Near Maximum Sliding Gate |
NUMP
| Number of Detection Passes |
RATE
| Firing Rate |
SDTH
| Switch Down Threshold |
SFAF
| Sonic Formation Attenuation Factor |
SGAD
| Sliding Gate Status |
SGAI
| Selectable Acquisition Gain |
SGCL
| Sliding Gate Closing Delta-T |
SGCW
| Sliding Gate Closing Width |
SGDT
| Sliding Gate Delta-T |
SGW
| Sliding Gate Width |
SLEV
| Signal Level for AGC |
SPFS
| Sonic Porosity Formula |
SPSO
| Sonic Porosity Source |
SUTH
| Switch Up Threshold |
VDLG
| VDL Manual Gain |
WAGC
| Waveform AGC Allow/Disallow |
WGAI
| Waveform Manual Gain |
WGDT
| Waveform Gain Delta-T |
WGIN
| Waveform Gain Interval |
WMOD
| Waveform Firing Mode |
ZCMT
| Acoustic Impedance of Cement |