| Parameter | Description |
|
C1_GAIN
| Calibration Gain Applied to Caliper 1 (or X) |
|
C1_OFFSET
| Calibration Offset Applied to Caliper 1 (or X) |
|
DP1S
| Probe 1 Allow/Disallow Switch |
|
DP2S
| Probe 2 Allow/Disallow Switch |
|
DP3S
| Probe 3 Allow/Disallow Switch |
|
DP4S
| Probe 4 Allow/Disallow Switch |
|
GGA1
| Downhole Signal Gain Optical Probe 1 |
|
GGA2
| Downhole Signal Gain Optical Probe 2 |
|
GGA3
| Downhole Signal Gain Optical Probe 3 |
|
GGA4
| Downhole Signal Gain Optical Probe 4 |
|
GHOST_DFX1
| Maximum Value during Probe 1 calibration |
|
GHOST_DFX2
| Maximum Value during Probe 2 calibration |
|
GHOST_DFX3
| Maximum Value during Probe 3 calibration |
|
GHOST_DFX4
| Maximum Value during Probe 4 calibration |
|
GHOST_GGA1
| Probe 1 Gain |
|
GHOST_GGA2
| Probe 2 Gain |
|
GHOST_GGA3
| Probe 3 Gain |
|
GHOST_GGA4
| Probe 4 Gain |
|
GHOST_GLPO
| Ghost Led power value computed during calibration |
|
GHOST_GOF1
| Probe 1 Offset |
|
GHOST_GOF2
| Probe 2 Offset |
|
GHOST_GOF3
| Probe 3 Offset |
|
GHOST_GOF4
| Probe 4 Offset |
|
GHOST_LEDP_INT
| GHOST internal parameter for led calibration |
|
GHOST_PROB_POS
| GHOST Probes Position (e.g. slot D, E) |
|
GLPW
| GHOST LED Power |
|
GOF1
| Downhole Signal Offset Optical Probe 1 |
|
GOF2
| Downhole Signal Offset Optical Probe 2 |
|
GOF3
| Downhole Signal Offset Optical Probe 3 |
|
GOF4
| Downhole Signal Offset Optical Probe 4 |
|
GTAD
| GHOST Threshold Auto Delta Min |
|
LARGE_RING
| Caliper Calibration Large Ring |
|
PFBV
| Bubble Velocity |
|
PFTH1
| Downhole Threshold Probe 1 |
|
PFTH2
| Downhole Threshold Probe 2 |
|
PFTH3
| Downhole Threshold Probe 3 |
|
PFTH4
| Downhole Threshold Probe 4 |
|
PFTHM
| Threshold Mode |
|
SDCF
| Spinner Depth Constant Filter |
|
SMALL_RING
| Caliper Calibration Small Ring |