Mnemonics, Tools, GHOSTA_2


CodeGHOSTA_2
TechnologyFlowmeter
DisciplineProduction
MethodWIRELINE
DescriptionGas Holdup Optical Sensing Tool - A (2nd GHOST-A in tool string)

Related channels
ChannelDescription
DFN5 DEFT waveform minimum value probe 1
DFN5_SL DEFT Waveform Minimum Value Probe 1 - Station Log
DFN6 DEFT Waveform Minimum Value Probe 2
DFN6_SL DEFT Waveform Minimum Value Probe 2 - Station Log
DFN7 DEFT Waveform Minimum Value Probe 3
DFN7_SL DEFT Waveform Minimum Value Probe 3 - Station Log
DFN8 DEFT Waveform Minimum Value Probe 4
DFN8_SL DEFT Waveform Minimum Value Probe 4 - Station Log
DFRB2 2nd DEFT Calibrated Relative Bearing
DFRB2_SL 2nd DEFT Calibrated Relative Bearing - Station Log
DFX5 Waveform Maximum Amplitude Probe 5
DFX5_SL Waveform Maximum Amplitude Probe 5 - Station Log
DFX6 Waveform Maximum Amplitude Probe 6
DFX6_SL Waveform Maximum Amplitude Probe 6 - Station Log
DFX7 Waveform Maximum Amplitude Probe 7
DFX7_SL Waveform Maximum Amplitude Probe 7 - Station Log
DFX8 Waveform Maximum Amplitude Probe 8
DFX8_SL Waveform Maximum Amplitude Probe 8 - Station Log
DGFBM Dual GHOST Bubble Count Average
DGFBM_SL Dual GHOST Bubble Count Average - Station log
DGFHM Dual GHOST Holdup Average
DGFHM_SL Dual GHOST Holdup Average - Station log
DP5S 2nd DEFT Probe 1 Allow/Disallow Switch
DP5S_SL 2nd DEFT Probe 1 Allow/Disallow Switch - Station Log
DP6S 2nd DEFT Probe 2 Allow/Disallow Switch
DP6S_SL 2nd DEFT Probe 2 Allow/Disallow Switch - Station Log
DP7S 2nd DEFT Probe 3 Allow/Disallow Switch
DP7S_SL 2nd DEFT Probe 3 Allow/Disallow Switch - Station Log
DP8S 2nd DEFT Probe 4 Allow/Disallow Switch
DP8S_SL 2nd DEFT Probe 4 Allow/Disallow Switch - Station Log
GFBM2 GHOST-2 Filtered Bubble Count Rate Average
GFBM2_SL GHOST-2 Filtered Bubble Count Rate Average - Station Log
GFHM2 GHOST-2 Gas Filtered Holdup Average
GFHM2_SL GHOST-2 Gas Filtered Holdup Average - Station Log
GHB5 Bubble Count Rate Optical Probe 5
GHB5_SL GHOST Bubble Count Rate Probe 5 - Station Log
GHB6 GHOST Bubble Count Rate Probe 6
GHB6_SL GHOST Bubble Count Rate Probe 6 - Station Log
GHB7 GHOST Bubble Count Rate Probe 7
GHB7_SL GHOST Bubble Count Rate Probe 7 - Station Log
GHB8 GHOST Bubble Count Rate Probe 8
GHB8_SL GHOST Bubble Count Rate Probe 8 - Station Log
GHBM2 GHOST-2 Bubble Count Rate Average
GHBM2_SL GHOST-2 Bubble Count Rate Average - Station Log
GHH5 Gas Holdup Optical Probe 5
GHH5_SL Gas Holdup Probe 5 - Station Log
GHH6 Gas Holdup Probe 6
GHH6_SL Gas Holdup Probe 6 - Station Log
GHH7 Gas Holdup Probe 7
GHH7_SL Gas Holdup Probe 7 - Station Log
GHH8 Gas Holdup Probe 8
GHH8_SL Gas Holdup Probe 8 - Station Log
GHHM2 GHOST-2 Gas Holdup Average
GHHM2_SL GHOST-2 Gas Holdup Average - Station Log
PFC12 Caliper X (2nd tool)
PFC12_SL Caliper X - Station log (2nd tool)
PFTH5 Downhole Water/Oil Threshold Probe 5
PFTH5_SL Downhole Water/Oil Threshold Probe 5 - Station Log
PFTH6 Downhole Water/Oil Threshold Probe 6
PFTH6_SL Downhole Water/Oil Threshold Probe 6 - Station Log
PFTH7 Downhole Water/Oil Threshold Probe 7
PFTH7_SL Downhole Water/Oil Threshold Probe 7 - Station Log
PFTH8 Downhole Water/Oil Threshold Probe 8
PFTH8_SL Downhole Water/Oil Threshold Probe 8 - Station Log
RB_GHOSTA_2 Relative Bearing Memorized at GHOSTA_2
RPFCX2 Uncalibrated Caliper X (2nd tool)
RPFCX2_SL Uncalibrated Caliper X - Station log (2nd tool)

Related parameters
ParameterDescription
GGA5 Downhole Signal Gain Optical Probe 5
GGA6 Downhole Signal Gain Probe 6
GGA7 Downhole Signal Gain Probe 7
GGA8 Downhole Signal Gain Probe 8
GLPW2 GHOST-2 LED Power
GOF5 Downhole Signal Offset Optical Probe 5
GOF6 Downhole Signal Offset Probe 6
GOF7 Downhole Signal Offset Probe 7
GOF8 Downhole Signal Offset Probe 8
GTAD GHOST Threshold Auto Delta Min
GTHM GHOST Downhole Threshold Mode
PFBV Bubble Velocity
PFPO2 Tool Position on CAN Bus (2nd tool)
PFTH5 Downhole Water/Oil Threshold Probe 5
PFTH6 Downhole Water/Oil Threshold Probe 6
PFTH7 Downhole Water/Oil Threshold Probe 7
PFTH8 Downhole Water/Oil Threshold Probe 8
PFWS2 Waveform Status (2nd tool)


Return to Curve Mnemonic Dictionary