Mnemonics, Tools, MIFA-ND


CodeMIFA-ND
TechnologySampling
DisciplineWell Testing
MethodWIRELINE
DescriptionModular InSitu Fluid Analyzer

Related channels
ChannelDescription
BOPH Optical Density Baseline
CCEXP Composition Fluid Coloration Exponent
CCQI Composite Hydrocarbon Composition Quality Indicator
CFCOL Composition Fluid Coloration
CHCCR Cumulative Hydrocarbon and CO2 Composition Ratio
CHCR Cumulative Hydrocarbon Composition Ratio
CO2QI Carbon Dioxide Ratio Quality Indicator
CO2R Ratio of CO2 Partial Density to Partial Density of Hydrocarbon + CO2
CODSC Composition Optical Density Scattering Component
ETHNR Ratio of Ethane Partial Density to Partial Density of Hydrocarbon + CO2
FCOL Fluid Coloration
FFRES Flowline Fluid Resistivity
FL0IMG Fluorescence Channel 0 Image
FL1IMG Fluorescence Channel 1 Image
FLI0 Fluorescence Intensity 0
FLI1 Fluorescence Intensity 1
FLR Fluorescence Reflection
FRAT Fluorescence Ratio
FSOD Filter Array Spectrometer Optical Density
FSODGT Filter Spectrometer Optical Density with Graphics Transform
FSODIMG Filter Array Spectrometer Optical Density Image
GASFLG Gas Flag
GOR Gas Oil Ratio
GORQI Gas Oil Ratio Quality Indicator
GSODGT Grating Spectrometer Optical Density with Graphics Transform
GSODIMG Grating Spectrometer Optical Density Image
HAFF Highly Absorbing Fluid Flag
HCAF Hydrocarbon Composition Algorithm Flag
HCAW Hydrocarbon Composition Algorithm Weight
HCQI Hydrocarbon Quality Indicator
HEXR Ratio of C6+ Partial Density to Partial Density of Hydrocarbon + CO2
HLCO2R High Limit of Ratio of CO2 Partial Density to Partial Density of Hydrocarbon + CO2
LEGS Live Fluid Aanalyzer Equivalent Green Shade
LLCO2R Low Limit of Ratio of CO2 Partial Density to Partial Density of Hydrocarbon + CO2
METHR Ratio of Methane Partial Density to Partial Density of Hydrocarbon + CO2
ODDIFF1IMG pH Optical Density Difference 1
ODDIFF2IMG pH Optical Density Difference 2
ODDIFF3IMG pH Optical Density Difference 3
OPTCWF Coated Window Flag
PHDI pH from Dye Indicator
PHDS pH Analysis Detailed Status
PHOR pH Optical Density Ratio
PHSS pH Analysis Summary Status
PRTPR Ratio of C3-C4-C5 Partial Density to Partial Density of Hydrocarbon + CO2
RC_ACOM_COEFS Resistivity Cell Automatic Compensation Coefficients
RCFRQ Resistivity Cell Frequency
RCTEMP Resistivity Cell Temperature
RFFRES Raw Flowline Fluid Resistivity
RODCONF DV-Rod Confidence Factor
RODDQUAL DV-Rod Density Quality Flag
RODF0 DV-Rod Resonance Frequency
RODQ DV-Rod Quality Factor
RODRHO DV-Rod Fluid Density
RODRRHO DV-Rod Raw Fluid Density
RODRTEMP DV-Rod Raw Temperature
RODTEMP DV-Rod Temperature
RODURHO DV-Rod Unsmooth Fluid Density
RODUVIS DV-Rod Unsmooth Fluid Viscosity
RODVIS DV-Rod Fluid Viscosity
RODVQUAL DV-Rod Viscosity Quality Flag
RRESB4ACOM Raw Resistivity Before Applying ACOM Coefficients
SOIPRES SOI Gauge Pressure
SOITEMP SOI Temperature
STOTYP Stock Tank Oil Type
UCO2R Uncertainty in Ratio of CO2 Partial Density to Partial Density of Hydrocarbon + CO2
VFID Volume Fraction Image Display
VWCOMPSTA Vibrating Wire Computation Status
VWFRHOIN Vibrating Wire Fluid Density Input
VWFTEMP Vibrating Wire Flowline Fluid Temperature
VWLDMDEC Vibrating Wire Linear Damping Model Decrement
VWLDMFREQ Vibrating Wire Linear Damping Model Frequency
VWNDMDEC Vibrating Wire Non-Linear Damping Model Decrement
VWNDMFREQ Vibrating Wire Non-Linear Damping Model Frequency
VWQD Vibrating Wire Viscosity Detailed Quality Indicator
VWQDI Vibrating Wire Viscosity Detailed Quality Indicator
VWQI Vibrating Wire Viscosity Quality Indicator
VWUFTEMP Vibrating Wire Unsmoothed Flowline Fluid Temperature
VWUQI Vibrating Wire Unsmoothed Viscosity Quality Indicator
VWUVIS Vibrating Wire Unsmoothed Fluid Viscosity
VWVIS Vibrating Wire Fluid Viscosity
WATF Water Fraction

Related parameters
ParameterDescription
CC_FS10_GS4_OIL Oil OD Cross Check (FS10 - FS9) - (GS4 - GS1)
CC_FS10_GS4_WATER Water OD Cross Check (FS10 - FS12) - (GS4 - GS6)
CC_FS11_GS5_OIL Oil OD Cross Check (FS11 - FS9) - (GS5 - GS1)
CC_FS11_GS5_WATER Water OD Cross Check (FS11 - FS12) - (GS5 - GS6)
CC_FS12_GS7_OIL Oil OD Cross Check (FS12 - FS9) - (GS7 - GS1)
CC_FS12_GS7_WATER Water OD Cross Check (FS12 - FS12) - (GS7 - GS6)
CC_FS13_GS9_OIL Oil OD Cross Check (FS13 - FS9) - (GS9 - GS1)
CC_FS13_GS9_WATER Water OD Cross Check (FS13 - FS12) - (GS9 - GS6)
CC_FS14_GS11_OIL Oil OD Cross Check (FS14 - FS9) - (GS11 - GS1)
CC_FS14_GS11_WATER Water OD Cross Check (FS14 - FS12) - (GS11 - GS6)
CC_FS15_GS14_OIL Oil OD Cross Check (FS15 - FS9) - (GS14 - GS1)
CC_FS15_GS14_WATER Water OD Cross Check (FS15 - FS12) - (GS14 - GS6)
CELL_THK_COEFF Cell Thickness Coefficients
CO2RCOMP CO2 Ratio Computation
COLEXP Coloration Exponent
DACF_BB Dye Absorbance Calibration Factor for Bromophenol Blue
DACF_CPR Dye Absorbance Calibration Factor for Chlorophenol Red
DACF_PR Dye Absorbance Calibration Factor for Phenol Red
DC_BB Dye Concentration for Bromophenol Blue
DC_CPR Dye Concentration for Chlorophenol Red
DC_PR Dye Concentration for Phenol Red
DIFF_FS_NORM_OD_OIL Difference of Filter Array Spectrometer Oil OD Normalized by FS9 from Most Recent One
DIFF_FSLM_DRY Difference of Filter Array Spectrometer Negative Log Measure/Source Ratio Master Calibration Dry Measurement from Most Recent One
DIFF_FSLM_RT_DRY Difference between Filter Array Spectrometer Negative Log Measure/Source Ratio Room Temperature Measurement and Dry Measurement
DIFF_FSLM_SHIFT_100C Difference of Filter Array Spectrometer Negative Log Measure/Source Ratio Shift Temperature Compensation 100C from Most Recent One
DIFF_FSLM_SHIFT_125C Difference of Filter Array Spectrometer Negative Log Measure/Source Ratio Shift Temperature Compensation 125C from Most Recent One
DIFF_FSLM_SHIFT_150C Difference of Filter Array Spectrometer Negative Log Measure/Source Ratio Shift Temperature Compensation 150C from Most Recent One
DIFF_FSLM_SHIFT_175C Difference of Filter Array Spectrometer Negative Log Measure/Source Ratio Shift Temperature Compensation 175C from Most Recent One
DIFF_FSLM_SHIFT_75C Difference of Filter Array Spectrometer Negative Log Measure/Source Ratio Shift Temperature Compensation 75C from Most Recent One
DIFF_GS_NORM_OD_OIL Difference of Grating Spectrometer Oil OD Normalized by GS1 from Most Recent One
DIFF_GSLM_DRY Difference of Grating Spectrometer Negative Log Measure/Source Ratio Master Calibration Dry Measurement from Most Recent One
DIFF_GSLM_RT_DRY Difference between Grating Spectrometer Negative Log Measure/Source Ratio Room Temperature Measurement and Dry Measurement
DIFF_GSLM_SHIFT_100C Difference of Grating Spectrometer Negative Log Measure/Source Ratio Shift Temperature Compensation 100C from Most Recent One
DIFF_GSLM_SHIFT_125C Difference of Grating Spectrometer Negative Log Measure/Source Ratio Shift Temperature Compensation 125C from Most Recent One
DIFF_GSLM_SHIFT_150C Difference of Grating Spectrometer Negative Log Measure/Source Ratio Shift Temperature Compensation 150C from Most Recent One
DIFF_GSLM_SHIFT_175C Difference of Grating Spectrometer Negative Log Measure/Source Ratio Shift Temperature Compensation 175C from Most Recent One
DIFF_GSLM_SHIFT_75C Difference of Grating Spectrometer Negative Log Measure/Source Ratio Shift Temperature Compensation 75C from Most Recent One
DIFF_RFLI0_R6G Difference of Raw Fluorescence Channel #0 Master Calibration Rhodamine 6G Measurement from Most Recent One
DIFF_RFLR_DRY Difference of Raw Fluorescence Reflection Master Calibration Dry Measurement from Most Recent One
DMID Dye Mixture Identifier
DWIS Dye Working Ionic Strength
FDT_100C Fluorescence Detector Temperature Temperature Compensation 100C
FDT_125C Fluorescence Detector Temperature Temperature Compensation 125C
FDT_150C Fluorescence Detector Temperature Temperature Compensation 150C
FDT_175C Fluorescence Detector Temperature Temperature Compensation 175C
FDT_75C Fluorescence Detector Temperature Temperature Compensation 75C
FDT_DRY Fluorescence Detector Temperature Master Calibration Dry Measurement
FDT_OIL Fluorescence Detector Temperature Master Calibration Oil Measurement
FDT_R6G Fluorescence Detector Temperature Master Calibration Rhodamine 6G Measurement
FDT_RT Fluorescence Detector Temperature Temperature Compensation Room Temperature
FDT_WATER Fluorescence Detector Temperature Master Calibration Water Measurement
FLIM_100C Fluorescence Intensity Monitor Temperature Compensation 100C
FLIM_125C Fluorescence Intensity Monitor Temperature Compensation 125C
FLIM_150C Fluorescence Intensity Monitor Temperature Compensation 150C
FLIM_175C Fluorescence Intensity Monitor Temperature Compensation 175C
FLIM_75C Fluorescence Intensity Monitor Temperature Compensation 75C
FLIM_DRY Fluorescence Intensity Monitor Master Calibration Dry Measurement
FLIM_R6G Fluorescence Intensity Monitor Master Calibration Rhodamine 6G Measurement
FLIM_RT Fluorescence Intensity Monitor Temperature Compensation Room Temperature
FLR_INTERCEPT Fluorescence Temperature Compensation Intercept Coefficient
FLR_NORMALIZED Fluorescence Temperature Compensation Normalized Slope Coefficient
FLR_SLOPE Fluorescence Temperature Compensation Slope Coefficient
FS_NORM_OD_OIL Filter Array Spectrometer Oil OD Normalized by FS9
FS_NORM_OD_WATER Filter Array Spectrometer Water OD Normalized by FS5
FS_OIL_ABS Filter Array Spectrometer Oil Absorption Coefficient
FS_WATER_ABS Filter Array Spectrometer Water Absorption Coefficient
FSDI_DRY Filter Array Spectrometer Dark Path Intensity Master Calibration Dry Measurement
FSLM_100C Filter Array Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 100C
FSLM_125C Filter Array Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 125C
FSLM_150C Filter Array Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 150C
FSLM_175C Filter Array Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 175C
FSLM_75C Filter Array Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 75C
FSLM_DRY Filter Array Spectrometer Negative Log Measure/Source Ratio Master Calibration Dry Measurement
FSLM_OIL Filter Array Spectrometer Negative Log Measure/Source Ratio Master Calibration Oil Measurement
FSLM_RT Filter Array Spectrometer Negative Log Measure/Source Ratio Temperature Compensation Room Temperature
FSLM_SHIFT_100C Shift of Filter Array Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 100C from Room Temperature
FSLM_SHIFT_125C Shift of Filter Array Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 125C from Room Temperature
FSLM_SHIFT_150C Shift of Filter Array Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 150C from Room Temperature
FSLM_SHIFT_175C Shift of Filter Array Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 175C from Room Temperature
FSLM_SHIFT_75C Shift of Filter Array Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 75C from Room Temperature
FSLM_WATER Filter Array Spectrometer Negative Log Measure/Source Ratio Master Calibration Water Measurement
FSMI_DRY Filter Array Spectrometer Measure Path Intensity Master Calibration Dry Measurement
FSMI_MINUS_FSDI_DRY Filter Array Spectrometer Measure - Dark Master Calibration Dry Measurement
FSSI_DRY Filter Array Spectrometer Source Path Intensity Master Calibration Dry Measurement
FSSI_MINUS_FSDI_100C Filter Array Spectrometer Source - Dark Temperature Compensation 100C
FSSI_MINUS_FSDI_125C Filter Array Spectrometer Source - Dark Temperature Compensation 125C
FSSI_MINUS_FSDI_150C Filter Array Spectrometer Source - Dark Temperature Compensation 150C
FSSI_MINUS_FSDI_175C Filter Array Spectrometer Source - Dark Temperature Compensation 75C
FSSI_MINUS_FSDI_75C Filter Array Spectrometer Source - Dark Temperature Compensation 75C
FSSI_MINUS_FSDI_DRY Filter Array Spectrometer Source - Dark Master Calibration Dry Measurement
FSSI_MINUS_FSDI_RT Filter Array Spectrometer Source - Dark Temperature Compensation Room Temperature
FSWLO Filter Array Spectrometer Channel Wavelength Offset
GS_NORM_OD_OIL Grating Spectrometer Oil OD Normalized by GS1
GS_NORM_OD_WATER Grating Spectrometer Water OD Normalized by GS6
GS_OIL_ABS Grating Spectrometer Oil Absorption Coefficient
GS_WATER_ABS Grating Spectrometer Water Absorption Coefficient
GSDI_DRY Grating Spectrometer Dark Path Intensity Master Calibration Dry Measurement
GSLM_100C Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 100C
GSLM_125C Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 125C
GSLM_150C Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 150C
GSLM_175C Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 175C
GSLM_75C Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 75C
GSLM_DRY Grating Spectrometer Negative Log Measure/Source Ratio Master Calibration Dry Measurement
GSLM_NORM_100C Shift of Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 100C from Room Temperature Normalized by GS1
GSLM_NORM_125C Shift of Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 125C from Room Temperature Normalized by GS1
GSLM_NORM_150C Shift of Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 150C from Room Temperature Normalized by GS1
GSLM_NORM_175C Shift of Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 175C from Room Temperature Normalized by GS1
GSLM_NORM_75C Shift of Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 75C from Room Temperature Normalized by GS1
GSLM_OIL Grating Spectrometer Negative Log Measure/Source Ratio Master Calibration Oil Measurement
GSLM_RT Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation Room Temperature
GSLM_SHIFT_100C Shift of Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 100C from Room Temperature
GSLM_SHIFT_125C Shift of Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 125C from Room Temperature
GSLM_SHIFT_150C Shift of Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 150C from Room Temperature
GSLM_SHIFT_175C Shift of Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 175C from Room Temperature
GSLM_SHIFT_75C Shift of Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 75C from Room Temperature
GSLM_WATER Grating Spectrometer Negative Log Measure/Source Ratio Master Calibration Water Measurement
GSMI_DRY Grating Spectrometer Measure Path Intensity Master Calibration Dry Measurement
GSMI_MINUS_GSDI_DRY Grating Spectrometer Measure - Dark Master Calibration Dry Measurement
GSSI_DRY Grating Spectrometer Source Path Intensity Master Calibration Dry Measurement
GSSI_MINUS_GSDI_100C Grating Spectrometer Source - Dark Temperature Compensation 100C
GSSI_MINUS_GSDI_125C Grating Spectrometer Source - Dark Temperature Compensation 125C
GSSI_MINUS_GSDI_150C Grating Spectrometer Source - Dark Temperature Compensation 150C
GSSI_MINUS_GSDI_175C Grating Spectrometer Source - Dark Temperature Compensation 175C
GSSI_MINUS_GSDI_75C Grating Spectrometer Source - Dark Temperature Compensation 75C
GSSI_MINUS_GSDI_DRY Grating Spectrometer Source - Dark Master Calibration Dry Measurement
GSSI_MINUS_GSDI_RT Grating Spectrometer Source - Dark Temperature Compensation Room Temperature
GSWLO Grating Spectrometer Channel Wavelength Offset
ODTHK Optical Density Cell Thickness Correction
ODTMPFS Filter Array Spectrometer Optical Density Temperature Correction
ODTMPGS Grating Spectrometer Optical Density Temperature Correction
PORT_NUMBER Serial Periferal Interface Port Number
PORT_NUMBER2 Serial Periferal Interface Port Number2
RFIL Resistivity Filter
RFL0_DRY Raw Fluorescence Channel #0 Master Calibration Dry Measurement
RFL0_R6G Raw Fluorescence Channel #0 Master Calibration Rhodamine 6G Measurement
RFL1_DRY Raw Fluorescence Channel #1 Master Calibration Dry Measurement
RFL1_R6G Raw Fluorescence Channel #1 Master Calibration Rhodamine 6G Measurement
RFLR_100C Raw Fluorescence Reflection Temperature Compensation 100C
RFLR_125C Raw Fluorescence Reflection Temperature Compensation 125C
RFLR_150C Raw Fluorescence Reflection Temperature Compensation 150C
RFLR_175C Raw Fluorescence Reflection Temperature Compensation 175C
RFLR_75C Raw Fluorescence Reflection Temperature Compensation 75C
RFLR_DRY Raw Fluorescence Reflection Master Calibration Dry Measurement
RFLR_R6G Raw Fluorescence Reflection Master Calibration Rhodamine 6G Measurement
RFLR_RT Raw Fluorescence Reflection Temperature Compensation Room Temperature
RODCALTEMP DV-Rod Calibration Temperature
RODCDATE DV-Rod Calibration Date
RODDCA DV-Rod Density Correction Applied
RODF0V DV-Rod Vacuum Resonance Frequency
RODFIT DV-Rod FIT Coefficients
RODHIQ DV-Rod High Quality Threshold
RODQV DV-Rod Vacuum Quality Factor
RODSERIAL DV-Rod Serial Number
SENSOR_SLOT Sensor Slot Selection
SENSOR_TYPE Serial Periferal Interface Sensor Type
TC_RODQ_AIR DV-Rod Quality Factor Mode 1 Air Check
TC_RODRHO_AIR DV-Rod Fluid Density Air Check
TC_RODRHO_OIL DV-Rod Fluid Density Oil Check
TC_RODRHO_WAT DV-Rod Fluid Density Water Check
TC_RODTEMP_OIL DV-Rod Temperature Oil Check
TC_RODTEMP_WAT DV-Rod Temperature Water Check
TC_RODVIS_OIL DV-Rod Fluid Viscosity Oil Check
TC_RODVIS_WAT DV-Rod Fluid Viscosity Water Check
TEMP Temperature
VWFRHOIN Vibrating Wire Fluid Density Input
VWFRHOSEL Vibrating Wire Fluid Density Input Selection
VWFRHOSO Vibrating Wire Fluid Density Source
VWFTEMP_SQA Vibrating Wire Flowline Fluid Temperature - Squalane Check
VWLDMDEC_AIR Vibrating Wire Linear Damping Model Decrement - Air Check
VWLDMFREQ_AIR Vibrating Wire Linear Damping Model Frequency - Air Check
VWLDMFREQ_SQA Vibrating Wire Linear Damping Model Frequency - Squalane Check
VWRDEC_AIR Vibrating Wire Reference Decrement for Air Check
VWRFREQ_AIR Vibrating Wire Reference Frequency for Air Check
VWTDELTA Vibrating Wire Temperature Calibration Coefficient Delta
VWTNSMT Vibrating Wire Temperature Number of Samples for Smoothing
VWTR0 Vibrating Wire Temperature Calibration Coefficient R0
VWTR100 Vibrating Wire Temperature Calibration Coefficient R100
VWVACDEC Vibrating Wire Vacuum Decrement
VWVIS_SQA Vibrating Wire Fluid Viscosity - Squalane Check
VWVNSMT Vibrating Wire Viscosity Number of Samples for Smoothing
VWWDENS Vibrating Wire Wire Density
VWWRAD Vibrating Wire Wire Radius


Return to Curve Mnemonic Dictionary