Mnemonics, Tools, MIFA-NX


CodeMIFA-NX
TechnologySampling
DisciplineWell Testing
MethodWIRELINE
DescriptionModular InSitu Fluid Analyzer

Related channels
ChannelDescription
BOPH Optical Density Baseline
BOPH_IFAX1 IFAX 1 Optical Density Baseline
BOPH_IFAX2 IFAX 2 Optical Density Baseline
CCEXP Composition Fluid Coloration Exponent
CCEXP_IFAX1 IFAX 1 Composition Fluid Coloration Exponent
CCEXP_IFAX2 IFAX 2 Composition Fluid Coloration Exponent
CCQI Composite Hydrocarbon Composition Quality Indicator
CCQI_IFAX1 IFAX 1 Composite Hydrocarbon Composition Quality Indicator
CCQI_IFAX2 IFAX 2 Composite Hydrocarbon Composition Quality Indicator
CFCOL Composition Fluid Coloration
CFCOL_IFAX1 IFAX 1 Composition Fluid Coloration
CFCOL_IFAX2 IFAX 2 Composition Fluid Coloration
CHCCR Cumulative Hydrocarbon and CO2 Composition Ratio
CHCCR_IFAX1 IFAX 1 Cumulative Hydrocarbon and CO2 Composition Ratio
CHCCR_IFAX2 IFAX 2 Cumulative Hydrocarbon and CO2 Composition Ratio
CHCR Cumulative Hydrocarbon Composition Ratio
CHCR_IFAX1 IFAX 1 Cumulative Hydrocarbon Composition Ratio
CHCR_IFAX2 IFAX 2 Cumulative Hydrocarbon Composition Ratio
CO2QI Carbon Dioxide Ratio Quality Indicator
CO2QI_IFAX1 IFAX 1 Carbon Dioxide Ratio Quality Indicator
CO2QI_IFAX2 IFAX 2 Carbon Dioxide Ratio Quality Indicator
CO2R Ratio of CO2 Partial Density to Partial Density of Hydrocarbon + CO2
CO2R_IFAX1 IFAX 1 Ratio of CO2 Partial Density to Partial Density of Hydrocarbon + CO2
CO2R_IFAX2 IFAX 2 Ratio of CO2 Partial Density to Partial Density of Hydrocarbon + CO2
CODSC Composition Optical Density Scattering Component
CODSC_IFAX1 IFAX 1 Composition Optical Density Scattering Component
CODSC_IFAX2 IFAX 2 Composition Optical Density Scattering Component
ETHAR_IFAX1 IFAX 1 Ratio of Ethane Partial Density to Partial Density of Hydrocarbon + CO2
ETHAR_IFAX2 IFAX 2 Ratio of Ethane Partial Density to Partial Density of Hydrocarbon + CO2
ETHNR Ratio of Ethane Partial Density to Partial Density of Hydrocarbon + CO2
FCOL Fluid Coloration
FCOL_IFAX1 IFAX 1 Fluid Coloration
FCOL_IFAX2 IFAX 2 Fluid Coloration
FFRES Flowline Fluid Resistivity
FFRES_IFAX1 IFAX 1 Flowline Fluid Resistivity
FFRES_IFAX2 IFAX 2 Flowline Fluid Resistivity
FL0_IFAX1 IFAX 1 Fluorescence Intensity 0
FL0_IFAX2 IFAX 2 Fluorescence Intensity 0
FL0IMG Fluorescence Channel 0 Image
FL0IMG_IFAX1 IFAX 1 Fluorescence Channel 0 Image
FL0IMG_IFAX2 IFAX 2 Fluorescence Channel 0 Image
FL1_IFAX1 IFAX 1 Fluorescence Intensity 1
FL1_IFAX2 IFAX 2 Fluorescence Intensity 1
FL1IMG Fluorescence Channel 1 Image
FL1IMG_IFAX1 IFAX 1 Fluorescence Channel 1 Image
FL1IMG_IFAX2 IFAX 2 Fluorescence Channel 1 Image
FLI0 Fluorescence Intensity 0
FLI1 Fluorescence Intensity 1
FLR Fluorescence Reflection
FLR_IFAX1 IFAX 1 Fluorescence Reflection
FLR_IFAX2 IFAX 2 Fluorescence Reflection
FRAT Fluorescence Ratio
FRAT_IFAX1 IFAX 1 Fluorescence Ratio
FRAT_IFAX2 IFAX 2 Fluorescence Ratio
FSODGT Filter Spectrometer Optical Density with Graphics Transform
FSODIMG Filter Array Spectrometer Optical Density Image
FXOD Filter Array Spectrometer X Optical Density
FXOD_IFAX1 IFAX 1 Filter Array Spectrometer X Optical Density
FXOD_IFAX2 IFAX 2 Filter Array Spectrometer X Optical Density
FXODGT_IFAX1 IFAX 1 Filter Spectrometer Optical Density with Graphics Transform
FXODGT_IFAX2 IFAX 2 Filter Spectrometer Optical Density with Graphics Transform
FXODIMG_IFAX1 IFAX 1 Filter Array Spectrometer Optical Density Image
FXODIMG_IFAX2 IFAX 2 Filter Array Spectrometer Optical Density Image
GASFLG Gas Flag
GASFLG_IFAX1 IFAX 1 Gas Flag
GASFLG_IFAX2 IFAX 2 Gas Flag
GOR Gas Oil Ratio
GOR_IFAX1 IFAX 1 Gas Oil Ratio
GOR_IFAX2 IFAX 2 Gas Oil Ratio
GORQI Gas Oil Ratio Quality Indicator
GORQI_IFAX1 IFAX 1 Gas Oil Ratio Quality Indicator
GORQI_IFAX2 IFAX 2 Gas Oil Ratio Quality Indicator
GSODGT Grating Spectrometer Optical Density with Graphics Transform
GSODGT_IFAX1 IFAX 1 Grating Spectrometer Optical Density with Graphics Transform
GSODGT_IFAX2 IFAX 2 Grating Spectrometer Optical Density with Graphics Transform
GSODIMG Grating Spectrometer Optical Density Image
GSODIMG_IFAX1 IFAX 1 Grating Spectrometer Optical Density Image
GSODIMG_IFAX2 IFAX 2 Grating Spectrometer Optical Density Image
HAFF Highly Absorbing Fluid Flag
HAFF_IFAX1 IFAX 1 Highly Absorbing Fluid Flag
HAFF_IFAX2 IFAX 2 Highly Absorbing Fluid Flag
HCAF Hydrocarbon Composition Algorithm Flag
HCAF_IFAX1 IFAX 1 Hydrocarbon Composition Algorithm Flag
HCAF_IFAX2 IFAX 2 Hydrocarbon Composition Algorithm Flag
HCAW Hydrocarbon Composition Algorithm Weight
HCAW_IFAX1 IFAX 1 Hydrocarbon Composition Algorithm Weight
HCAW_IFAX2 IFAX 2 Hydrocarbon Composition Algorithm Weight
HCQI Hydrocarbon Quality Indicator
HCQI_IFAX1 IFAX 1 Hydrocarbon Quality Indicator
HCQI_IFAX2 IFAX 2 Hydrocarbon Quality Indicator
HEXR Ratio of C6+ Partial Density to Partial Density of Hydrocarbon + CO2
HEXR_IFAX1 IFAX 1 Ratio of C6+ Partial Density to Partial Density of Hydrocarbon + CO2
HEXR_IFAX2 IFAX 2 Ratio of C6+ Partial Density to Partial Density of Hydrocarbon + CO2
HLCO2R High Limit of Ratio of CO2 Partial Density to Partial Density of Hydrocarbon + CO2
HLCO2R_IFAX1 IFAX 1 High Limit of Ratio of CO2 Partial Density to Partial Density of Hydrocarbon + CO2
HLCO2R_IFAX2 IFAX 2 High Limit of Ratio of CO2 Partial Density to Partial Density of Hydrocarbon + CO2
LEGS Live Fluid Aanalyzer Equivalent Green Shade
LEGS_IFAX1 IFAX 1 Live Fluid Aanalyzer Equivalent Green Shade
LEGS_IFAX2 IFAX 2 Live Fluid Aanalyzer Equivalent Green Shade
LLCO2R Low Limit of Ratio of CO2 Partial Density to Partial Density of Hydrocarbon + CO2
LLCO2R_IFAX1 IFAX 1 Low Limit of Ratio of CO2 Partial Density to Partial Density of Hydrocarbon + CO2
LLCO2R_IFAX2 IFAX 2 Low Limit of Ratio of CO2 Partial Density to Partial Density of Hydrocarbon + CO2
METHR Ratio of Methane Partial Density to Partial Density of Hydrocarbon + CO2
METHR_IFAX1 IFAX 1 Ratio of Methane Partial Density to Partial Density of Hydrocarbon + CO2
METHR_IFAX2 IFAX 2 Ratio of Methane Partial Density to Partial Density of Hydrocarbon + CO2
ODDIFF1IMG pH Optical Density Difference 1
ODDIFF1IMG_IFAX1 IFAX 1 pH Optical Density Difference 1
ODDIFF1IMG_IFAX2 IFAX 2 pH Optical Density Difference 1
ODDIFF2IMG pH Optical Density Difference 2
ODDIFF2IMG_IFAX1 IFAX 1 pH Optical Density Difference 2
ODDIFF2IMG_IFAX2 IFAX 2 pH Optical Density Difference 2
ODDIFF3IMG pH Optical Density Difference 3
ODDIFF3IMG_IFAX1 IFAX 1 pH Optical Density Difference 3
ODDIFF3IMG_IFAX2 IFAX 2 pH Optical Density Difference 3
OPTCWF Coated Window Flag
OPTCWF_IFAX1 IFAX 1 Coated Window Flag
OPTCWF_IFAX2 IFAX 2 Coated Window Flag
PHDI pH from Dye Indicator
PHDI_IFAX1 IFAX 1 pH from Dye Indicator
PHDI_IFAX2 IFAX 2 pH from Dye Indicator
PHDS pH Analysis Detailed Status
PHDS_IFAX1 IFAX 1 pH Analysis Detailed Status
PHDS_IFAX2 IFAX 2 pH Analysis Detailed Status
PHOR pH Optical Density Ratio
PHOR_IFAX1 IFAX 1 pH Optical Density Ratio
PHOR_IFAX2 IFAX 2 pH Optical Density Ratio
PHSS pH Analysis Summary Status
PHSS_IFAX1 IFAX 1 pH Analysis Summary Status
PHSS_IFAX2 IFAX 2 pH Analysis Summary Status
PRTPR Ratio of C3-C4-C5 Partial Density to Partial Density of Hydrocarbon + CO2
PRTPR_IFAX1 IFAX 1 Ratio of C3-C4-C5 Partial Density to Partial Density of Hydrocarbon + CO2
PRTPR_IFAX2 IFAX 2 Ratio of C3-C4-C5 Partial Density to Partial Density of Hydrocarbon + CO2
RC_ACOM_COEFS Resistivity Cell Automatic Compensation Coefficients
RCACOM_IFAX1 IFAX 1 Resistivity Cell Automatic Compensation Coefficients
RCACOM_IFAX2 IFAX 2 Resistivity Cell Automatic Compensation Coefficients
RCFRQ Resistivity Cell Frequency
RCFRQ_IFAX1 IFAX 1 Resistivity Cell Frequency
RCFRQ_IFAX2 IFAX 2 Resistivity Cell Frequency
RCTEMP Resistivity Cell Temperature
RCTEMP_IFAX1 IFAX 1 Resistivity Cell Temperature
RCTEMP_IFAX2 IFAX 2 Resistivity Cell Temperature
RFFRES Raw Flowline Fluid Resistivity
RFFRES_IFAX1 IFAX 1 Raw Flowline Fluid Resistivity
RFFRES_IFAX2 IFAX 2 Raw Flowline Fluid Resistivity
RODCONF DV-Rod Confidence Factor
RODCONF_IFAX1 IFAX 1 DV-Rod Confidence Factor
RODCONF_IFAX2 IFAX 2 DV-Rod Confidence Factor
RODDQUAL DV-Rod Density Quality Flag
RODDQUAL_IFAX1 IFAX 1 DV-Rod Density Quality Flag
RODDQUAL_IFAX2 IFAX 2 DV-Rod Density Quality Flag
RODF0 DV-Rod Resonance Frequency
RODF0_IFAX1 IFAX 1 DV-Rod Resonance Frequency
RODF0_IFAX2 IFAX 2 DV-Rod Resonance Frequency
RODQ DV-Rod Quality Factor
RODQ_IFAX1 IFAX 1 DV-Rod Quality Factor
RODQ_IFAX2 IFAX 2 DV-Rod Quality Factor
RODRHO DV-Rod Fluid Density
RODRHO_IFAX1 IFAX 1 DV-Rod Fluid Density
RODRHO_IFAX2 IFAX 2 DV-Rod Fluid Density
RODRRHO DV-Rod Raw Fluid Density
RODRRHO_IFAX1 IFAX 1 DV-Rod Raw Fluid Density
RODRRHO_IFAX2 IFAX 2 DV-Rod Raw Fluid Density
RODRTEMP DV-Rod Raw Temperature
RODRTEMP_IFAX1 IFAX 1 DV-Rod Raw Temperature
RODRTEMP_IFAX2 IFAX 2 DV-Rod Raw Temperature
RODTEMP DV-Rod Temperature
RODTEMP_IFAX1 IFAX 1 DV-Rod Temperature
RODTEMP_IFAX2 IFAX 2 DV-Rod Temperature
RODURHO DV-Rod Unsmooth Fluid Density
RODURHO_IFAX1 IFAX 1 DV-Rod Unsmooth Fluid Density
RODURHO_IFAX2 IFAX 2 DV-Rod Unsmooth Fluid Density
RODUVIS DV-Rod Unsmooth Fluid Viscosity
RODUVIS_IFAX1 IFAX 1 DV-Rod Unsmooth Fluid Viscosity
RODUVIS_IFAX2 IFAX 2 DV-Rod Unsmooth Fluid Viscosity
RODVIS DV-Rod Fluid Viscosity
RODVIS_IFAX1 IFAX 1 DV-Rod Fluid Viscosity
RODVIS_IFAX2 IFAX 2 DV-Rod Fluid Viscosity
RODVQUAL DV-Rod Viscosity Quality Flag
RODVQUAL_IFAX1 IFAX 1 DV-Rod Viscosity Quality Flag
RODVQUAL_IFAX2 IFAX 2 DV-Rod Viscosity Quality Flag
RRESB4ACOM Raw Resistivity Before Applying ACOM Coefficients
RRESB4ACOM_IFAX1 IFAX 1 Raw Resistivity Before Applying ACOM Coefficients
RRESB4ACOM_IFAX2 IFAX 2 Raw Resistivity Before Applying ACOM Coefficients
SOIPRES SOI Gauge Pressure
SOIPRES_IFAX1 IFAX 1 SOI Gauge Pressure
SOIPRES_IFAX2 IFAX 2 SOI Gauge Pressure
SOITEMP SOI Temperature
SOITEMP_IFAX1 IFAX 1 SOI Temperature
SOITEMP_IFAX2 IFAX 2 SOI Temperature
STOTYP Stock Tank Oil Type
STOTYP_IFAX1 IFAX 1 Stock Tank Oil Type
STOTYP_IFAX2 IFAX 2 Stock Tank Oil Type
UCO2R Uncertainty in Ratio of CO2 Partial Density to Partial Density of Hydrocarbon + CO2
UCO2R_IFAX1 IFAX 1 Uncertainty in Ratio of CO2 Partial Density to Partial Density of Hydrocarbon + CO2
UCO2R_IFAX2 IFAX 2 Uncertainty in Ratio of CO2 Partial Density to Partial Density of Hydrocarbon + CO2
VFID Volume Fraction Image Display
VFID_IFAX1 IFAX 1 Volume Fraction Image Display
VFID_IFAX2 IFAX 2 Volume Fraction Image Display
VWCOMPSTA Vibrating Wire Computation Status
VWFRHOIN Vibrating Wire Fluid Density Input
VWFTEMP Vibrating Wire Flowline Fluid Temperature
VWLDMDEC Vibrating Wire Linear Damping Model Decrement
VWLDMFREQ Vibrating Wire Linear Damping Model Frequency
VWNDMDEC Vibrating Wire Non-Linear Damping Model Decrement
VWNDMFREQ Vibrating Wire Non-Linear Damping Model Frequency
VWQD Vibrating Wire Viscosity Detailed Quality Indicator
VWQDI Vibrating Wire Viscosity Detailed Quality Indicator
VWQI Vibrating Wire Viscosity Quality Indicator
VWUFTEMP Vibrating Wire Unsmoothed Flowline Fluid Temperature
VWUQI Vibrating Wire Unsmoothed Viscosity Quality Indicator
VWUVIS Vibrating Wire Unsmoothed Fluid Viscosity
VWVIS Vibrating Wire Fluid Viscosity
WATF Water Fraction
WATF_IFAX1 IFAX 1 Water Fraction
WATF_IFAX2 IFAX 2 Water Fraction

Related parameters
ParameterDescription
CC_FX12_GS5_OIL Oil OD Cross Check (FS12 - FS11) - (GS5 - GS1)
CC_FX12_GS5_WATER Water OD Cross Check (FS12 - FS13) - (GS5 - GS6)
CC_FX13_GS7_OIL Oil OD Cross Check (FS13 - FS11) - (GS7 - GS1)
CC_FX13_GS7_WATER Water OD Cross Check (FS13 - FS13) - (GS7 - GS6)
CC_FX14_GS9_OIL Oil OD Cross Check (FS14 - FS11) - (GS9 - GS1)
CC_FX14_GS9_WATER Water OD Cross Check (FS14 - FS13) - (GS9 - GS6)
CC_FX15_GS11_OIL Oil OD Cross Check (FS15 - FS11) - (GS11 - GS1)
CC_FX15_GS11_WATER Water OD Cross Check (FS15 - FS13) - (GS11 - GS6)
CELL_THK_COEFF Cell Thickness Coefficients
CO2RCOMP CO2 Ratio Computation
CO2RCOMP_IFAX1 IFAX 1 CO2 Ratio Computation
CO2RCOMP_IFAX2 IFAX 2 CO2 Ratio Computation
COLEXP Coloration Exponent
COLEXP_IFAX1 IFAX 1 Coloration Exponent
COLEXP_IFAX2 IFAX 2 Coloration Exponent
DACF_BB Dye Absorbance Calibration Factor for Bromophenol Blue
DACF_BB_IFAX1 IFAX 1 Dye Absorbance Calibration Factor for Bromophenol Blue
DACF_BB_IFAX2 IFAX 2 Dye Absorbance Calibration Factor for Bromophenol Blue
DACF_CPR Dye Absorbance Calibration Factor for Chlorophenol Red
DACF_CPR_IFAX1 IFAX 1 Dye Absorbance Calibration Factor for Chlorophenol Red
DACF_CPR_IFAX2 IFAX 2 Dye Absorbance Calibration Factor for Chlorophenol Red
DACF_PR Dye Absorbance Calibration Factor for Phenol Red
DACF_PR_IFAX1 IFAX 1 Dye Absorbance Calibration Factor for Phenol Red
DACF_PR_IFAX2 IFAX 2 Dye Absorbance Calibration Factor for Phenol Red
DC_BB Dye Concentration for Bromophenol Blue
DC_BB_IFAX1 IFAX 1 Dye Concentration for Bromophenol Blue
DC_BB_IFAX2 IFAX 2 Dye Concentration for Bromophenol Blue
DC_CPR Dye Concentration for Chlorophenol Red
DC_CPR_IFAX1 IFAX 1 Dye Concentration for Chlorophenol Red
DC_CPR_IFAX2 IFAX 2 Dye Concentration for Chlorophenol Red
DC_PR Dye Concentration for Phenol Red
DC_PR_IFAX1 IFAX 1 Dye Concentration for Phenol Red
DC_PR_IFAX2 IFAX 2 Dye Concentration for Phenol Red
DIFF_FX_NORM_OD_OIL Difference of Filter Array Spectrometer X Oil OD Normalized by FS9 from Most Recent One
DIFF_FXLM_DRY Difference of Filter Array Spectrometer X Negative Log Measure/Source Ratio Master Calibration Dry Measurement from Most Recent One
DIFF_FXLM_RT_DRY Difference between Filter Array Spectrometer X Negative Log Measure/Source Ratio Room Temperature Measurement and Dry Measurement
DIFF_FXLM_SHIFT_100C Difference of Filter Array Spectrometer X Negative Log Measure/Source Ratio Shift Temperature Compensation 100C from Most Recent One
DIFF_FXLM_SHIFT_125C Difference of Filter Array Spectrometer X Negative Log Measure/Source Ratio Shift Temperature Compensation 125C from Most Recent One
DIFF_FXLM_SHIFT_150C Difference of Filter Array Spectrometer X Negative Log Measure/Source Ratio Shift Temperature Compensation 150C from Most Recent One
DIFF_FXLM_SHIFT_175C Difference of Filter Array Spectrometer X Negative Log Measure/Source Ratio Shift Temperature Compensation 175C from Most Recent One
DIFF_FXLM_SHIFT_75C Difference of Filter Array Spectrometer X Negative Log Measure/Source Ratio Shift Temperature Compensation 75C from Most Recent One
DIFF_GS_NORM_OD_OIL Difference of Grating Spectrometer Oil OD Normalized by GS1 from Most Recent One
DIFF_GSLM_DRY Difference of Grating Spectrometer Negative Log Measure/Source Ratio Master Calibration Dry Measurement from Most Recent One
DIFF_GSLM_RT_DRY Difference between Grating Spectrometer Negative Log Measure/Source Ratio Room Temperature Measurement and Dry Measurement
DIFF_GSLM_SHIFT_100C Difference of Grating Spectrometer Negative Log Measure/Source Ratio Shift Temperature Compensation 100C from Most Recent One
DIFF_GSLM_SHIFT_125C Difference of Grating Spectrometer Negative Log Measure/Source Ratio Shift Temperature Compensation 125C from Most Recent One
DIFF_GSLM_SHIFT_150C Difference of Grating Spectrometer Negative Log Measure/Source Ratio Shift Temperature Compensation 150C from Most Recent One
DIFF_GSLM_SHIFT_175C Difference of Grating Spectrometer Negative Log Measure/Source Ratio Shift Temperature Compensation 175C from Most Recent One
DIFF_GSLM_SHIFT_75C Difference of Grating Spectrometer Negative Log Measure/Source Ratio Shift Temperature Compensation 75C from Most Recent One
DIFF_RFLI0_R6G Difference of Raw Fluorescence Channel #0 Master Calibration Rhodamine 6G Measurement from Most Recent One
DIFF_RFLR_DRY Difference of Raw Fluorescence Reflection Master Calibration Dry Measurement from Most Recent One
DMID Dye Mixture Identifier
DMID_IFAX1 IFAX 1 Dye Mixture Identifier
DMID_IFAX2 IFAX 2 Dye Mixture Identifier
DWIS Dye Working Ionic Strength
DWIS_IFAX1 IFAX 1 Dye Working Ionic Strength
DWIS_IFAX2 IFAX 2 Dye Working Ionic Strength
FDT_100C Fluorescence Detector Temperature Temperature Compensation 100C
FDT_125C Fluorescence Detector Temperature Temperature Compensation 125C
FDT_150C Fluorescence Detector Temperature Temperature Compensation 150C
FDT_175C Fluorescence Detector Temperature Temperature Compensation 175C
FDT_75C Fluorescence Detector Temperature Temperature Compensation 75C
FDT_DRY Fluorescence Detector Temperature Master Calibration Dry Measurement
FDT_OIL Fluorescence Detector Temperature Master Calibration Oil Measurement
FDT_R6G Fluorescence Detector Temperature Master Calibration Rhodamine 6G Measurement
FDT_RT Fluorescence Detector Temperature Temperature Compensation Room Temperature
FDT_WATER Fluorescence Detector Temperature Master Calibration Water Measurement
FLIM_100C Fluorescence Intensity Monitor Temperature Compensation 100C
FLIM_125C Fluorescence Intensity Monitor Temperature Compensation 125C
FLIM_150C Fluorescence Intensity Monitor Temperature Compensation 150C
FLIM_175C Fluorescence Intensity Monitor Temperature Compensation 175C
FLIM_75C Fluorescence Intensity Monitor Temperature Compensation 75C
FLIM_DRY Fluorescence Intensity Monitor Master Calibration Dry Measurement
FLIM_R6G Fluorescence Intensity Monitor Master Calibration Rhodamine 6G Measurement
FLIM_RT Fluorescence Intensity Monitor Temperature Compensation Room Temperature
FLR_INTERCEPT Fluorescence Temperature Compensation Intercept Coefficient
FLR_NORMALIZED Fluorescence Temperature Compensation Normalized Slope Coefficient
FLR_SLOPE Fluorescence Temperature Compensation Slope Coefficient
FX_NORM_OD_OIL Filter Array Spectrometer X Oil OD Normalized by FS11
FX_NORM_OD_WATER Filter Array Spectrometer X Water OD Normalized by FS6
FX_OIL_ABS Filter Array Spectrometer X Oil Absorption Coefficient
FX_WATER_ABS Filter Array Spectrometer X Water Absorption Coefficient
FXDI_DRY Filter Array Spectrometer X Dark Path Intensity Master Calibration Dry Measurement
FXLM_100C Filter Array Spectrometer X Negative Log Measure/Source Ratio Temperature Compensation 100C
FXLM_125C Filter Array Spectrometer X Negative Log Measure/Source Ratio Temperature Compensation 125C
FXLM_150C Filter Array Spectrometer X Negative Log Measure/Source Ratio Temperature Compensation 150C
FXLM_175C Filter Array Spectrometer X Negative Log Measure/Source Ratio Temperature Compensation 175C
FXLM_75C Filter Array Spectrometer X Negative Log Measure/Source Ratio Temperature Compensation 75C
FXLM_DRY Filter Array Spectrometer X Negative Log Measure/Source Ratio Master Calibration Dry Measurement
FXLM_OIL Filter Array Spectrometer X Negative Log Measure/Source Ratio Master Calibration Oil Measurement
FXLM_RT Filter Array Spectrometer X Negative Log Measure/Source Ratio Temperature Compensation Room Temperature
FXLM_SHIFT_100C Shift of Filter Array Spectrometer X Negative Log Measure/Source Ratio Temperature Compensation 100C from Room Temperature
FXLM_SHIFT_125C Shift of Filter Array Spectrometer X Negative Log Measure/Source Ratio Temperature Compensation 125C from Room Temperature
FXLM_SHIFT_150C Shift of Filter Array Spectrometer X Negative Log Measure/Source Ratio Temperature Compensation 150C from Room Temperature
FXLM_SHIFT_175C Shift of Filter Array Spectrometer X Negative Log Measure/Source Ratio Temperature Compensation 175C from Room Temperature
FXLM_SHIFT_75C Shift of Filter Array Spectrometer X Negative Log Measure/Source Ratio Temperature Compensation 75C from Room Temperature
FXLM_WATER Filter Array Spectrometer X Negative Log Measure/Source Ratio Master Calibration Water Measurement
FXMI_DRY Filter Array Spectrometer X Measure Path Intensity Master Calibration Dry Measurement
FXMI_MINUS_FXDI_DRY Filter Array Spectrometer X Measure - Dark Master Calibration Dry Measurement
FXSI_DRY Filter Array Spectrometer X Source Path Intensity Master Calibration Dry Measurement
FXSI_MINUS_FXDI_100C Filter Array Spectrometer X Source - Dark Temperature Compensation 100C
FXSI_MINUS_FXDI_125C Filter Array Spectrometer X Source - Dark Temperature Compensation 125C
FXSI_MINUS_FXDI_150C Filter Array Spectrometer X Source - Dark Temperature Compensation 150C
FXSI_MINUS_FXDI_175C Filter Array Spectrometer X Source - Dark Temperature Compensation 175C
FXSI_MINUS_FXDI_75C Filter Array Spectrometer X Source - Dark Temperature Compensation 75C
FXSI_MINUS_FXDI_DRY Filter Array Spectrometer X Source - Dark Master Calibration Dry Measurement
FXSI_MINUS_FXDI_RT Filter Array Spectrometer X Source - Dark Temperature Compensation Room Temperature
FXWLO Filter Array Spectrometer X Channel Wavelength Offset
GS_NORM_OD_OIL Grating Spectrometer Oil OD Normalized by GS1
GS_NORM_OD_WATER Grating Spectrometer Water OD Normalized by GS6
GS_OIL_ABS Grating Spectrometer Oil Absorption Coefficient
GS_WATER_ABS Grating Spectrometer Water Absorption Coefficient
GSDI_DRY Grating Spectrometer Dark Path Intensity Master Calibration Dry Measurement
GSLM_100C Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 100C
GSLM_125C Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 125C
GSLM_150C Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 150C
GSLM_175C Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 175C
GSLM_75C Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 75C
GSLM_DRY Grating Spectrometer Negative Log Measure/Source Ratio Master Calibration Dry Measurement
GSLM_NORM_100C Shift of Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 100C from Room Temperature Normalized by GS1
GSLM_NORM_125C Shift of Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 125C from Room Temperature Normalized by GS1
GSLM_NORM_150C Shift of Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 150C from Room Temperature Normalized by GS1
GSLM_NORM_175C Shift of Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 175C from Room Temperature Normalized by GS1
GSLM_NORM_75C Shift of Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 75C from Room Temperature Normalized by GS1
GSLM_OIL Grating Spectrometer Negative Log Measure/Source Ratio Master Calibration Oil Measurement
GSLM_RT Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation Room Temperature
GSLM_SHIFT_100C Shift of Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 100C from Room Temperature
GSLM_SHIFT_125C Shift of Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 125C from Room Temperature
GSLM_SHIFT_150C Shift of Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 150C from Room Temperature
GSLM_SHIFT_175C Shift of Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 175C from Room Temperature
GSLM_SHIFT_75C Shift of Grating Spectrometer Negative Log Measure/Source Ratio Temperature Compensation 75C from Room Temperature
GSLM_WATER Grating Spectrometer Negative Log Measure/Source Ratio Master Calibration Water Measurement
GSMI_DRY Grating Spectrometer Measure Path Intensity Master Calibration Dry Measurement
GSMI_MINUS_GSDI_DRY Grating Spectrometer Measure - Dark Master Calibration Dry Measurement
GSSI_DRY Grating Spectrometer Source Path Intensity Master Calibration Dry Measurement
GSSI_MINUS_GSDI_100C Grating Spectrometer Source - Dark Temperature Compensation 100C
GSSI_MINUS_GSDI_125C Grating Spectrometer Source - Dark Temperature Compensation 125C
GSSI_MINUS_GSDI_150C Grating Spectrometer Source - Dark Temperature Compensation 150C
GSSI_MINUS_GSDI_175C Grating Spectrometer Source - Dark Temperature Compensation 175C
GSSI_MINUS_GSDI_75C Grating Spectrometer Source - Dark Temperature Compensation 75C
GSSI_MINUS_GSDI_DRY Grating Spectrometer Source - Dark Master Calibration Dry Measurement
GSSI_MINUS_GSDI_RT Grating Spectrometer Source - Dark Temperature Compensation Room Temperature
GSWLO Grating Spectrometer Channel Wavelength Offset
ODTHK Optical Density Cell Thickness Correction
ODTHK_IFAX1 IFAX 1 Optical Density Cell Thickness Correction
ODTHK_IFAX2 IFAX 2 Optical Density Cell Thickness Correction
ODTMPFS Filter Array Spectrometer Optical Density Temperature Correction
ODTMPFS_IFAX1 IFAX 1 Filter Array Spectrometer Optical Density Temperature Correction
ODTMPFS_IFAX2 IFAX 2 Filter Array Spectrometer Optical Density Temperature Correction
ODTMPGS Grating Spectrometer Optical Density Temperature Correction
ODTMPGS_IFAX1 IFAX 1 Grating Spectrometer Optical Density Temperature Correction
ODTMPGS_IFAX2 IFAX 2 Grating Spectrometer Optical Density Temperature Correction
PORT_NUMBER Serial Periferal Interface Port Number
PORT_NUMBER2 Serial Periferal Interface Port Number2
RFIL Resistivity Filter
RFIL_IFAX1 IFAX 1 Resistivity Filter
RFIL_IFAX2 IFAX 2 Resistivity Filter
RFL0_DRY Raw Fluorescence Channel #0 Master Calibration Dry Measurement
RFL0_R6G Raw Fluorescence Channel #0 Master Calibration Rhodamine 6G Measurement
RFL1_DRY Raw Fluorescence Channel #1 Master Calibration Dry Measurement
RFL1_R6G Raw Fluorescence Channel #1 Master Calibration Rhodamine 6G Measurement
RFLR_100C Raw Fluorescence Reflection Temperature Compensation 100C
RFLR_125C Raw Fluorescence Reflection Temperature Compensation 125C
RFLR_150C Raw Fluorescence Reflection Temperature Compensation 150C
RFLR_175C Raw Fluorescence Reflection Temperature Compensation 175C
RFLR_75C Raw Fluorescence Reflection Temperature Compensation 75C
RFLR_DRY Raw Fluorescence Reflection Master Calibration Dry Measurement
RFLR_R6G Raw Fluorescence Reflection Master Calibration Rhodamine 6G Measurement
RFLR_RT Raw Fluorescence Reflection Temperature Compensation Room Temperature
RODCALTEMP DV-Rod Calibration Temperature
RODCDATE DV-Rod Calibration Date
RODCDATE_IFAX1 IFAX 1 DV-Rod Calibration Date
RODCDATE_IFAX2 IFAX 2 DV-Rod Calibration Date
RODDCA DV-Rod Density Correction Applied
RODDCA_IFAX1 IFAX 1 DV-Rod Density Correction Applied
RODDCA_IFAX2 IFAX 2 DV-Rod Density Correction Applied
RODF0V DV-Rod Vacuum Resonance Frequency
RODFIT DV-Rod FIT Coefficients
RODHIQ DV-Rod High Quality Threshold
RODHIQ_IFAX1 IFAX 1 DV-Rod High Quality Threshold
RODHIQ_IFAX2 IFAX 2 DV-Rod High Quality Threshold
RODQV DV-Rod Vacuum Quality Factor
RODSERIAL DV-Rod Serial Number
RODSERIAL_IFAX1 IFAX 1 DV-Rod Serial Number
RODSERIAL_IFAX2 IFAX 2 DV-Rod Serial Number
SENSOR_SLOT Sensor Slot Selection
SENSOR_TYPE Serial Periferal Interface Sensor Type
TC_RODQ_AIR DV-Rod Quality Factor Mode 1 Air Check
TC_RODRHO_AIR DV-Rod Fluid Density Air Check
TC_RODRHO_OIL DV-Rod Fluid Density Oil Check
TC_RODRHO_WAT DV-Rod Fluid Density Water Check
TC_RODTEMP_OIL DV-Rod Temperature Oil Check
TC_RODTEMP_WAT DV-Rod Temperature Water Check
TC_RODVIS_OIL DV-Rod Fluid Viscosity Oil Check
TC_RODVIS_WAT DV-Rod Fluid Viscosity Water Check
TEMP Temperature
TEMP_IFAX1 IFAX 1 Temperature
TEMP_IFAX2 IFAX 2 Temperature
VWFRHOIN Vibrating Wire Fluid Density Input
VWFRHOSEL Vibrating Wire Fluid Density Input Selection
VWFRHOSO Vibrating Wire Fluid Density Source
VWFTEMP_SQA Vibrating Wire Flowline Fluid Temperature - Squalane Check
VWLDMDEC_AIR Vibrating Wire Linear Damping Model Decrement - Air Check
VWLDMFREQ_AIR Vibrating Wire Linear Damping Model Frequency - Air Check
VWLDMFREQ_SQA Vibrating Wire Linear Damping Model Frequency - Squalane Check
VWRDEC_AIR Vibrating Wire Reference Decrement for Air Check
VWRFREQ_AIR Vibrating Wire Reference Frequency for Air Check
VWTDELTA Vibrating Wire Temperature Calibration Coefficient Delta
VWTNSMT Vibrating Wire Temperature Number of Samples for Smoothing
VWTR0 Vibrating Wire Temperature Calibration Coefficient R0
VWTR100 Vibrating Wire Temperature Calibration Coefficient R100
VWVACDEC Vibrating Wire Vacuum Decrement
VWVIS_SQA Vibrating Wire Fluid Viscosity - Squalane Check
VWVNSMT Vibrating Wire Viscosity Number of Samples for Smoothing
VWWDENS Vibrating Wire Wire Density
VWWRAD Vibrating Wire Wire Radius


Return to Curve Mnemonic Dictionary