| Channel | Description |
|
AGAS
| Averaged Gas Indicator |
|
ANLCRSRC
| Analysis Creation Source |
|
CCNSTCOL
| Curve Fitting Constant C for Color |
|
CCNSTCUST
| Curve Fitting Constant C for Custom Interpretaton |
|
CCNSTMETH
| Curve Fitting Constant C for Methane |
|
CHANACOL
| Optical Density Channel A for Contamination Monitoring Color Model |
|
CHANACUST
| Channel A for Custom Interpretation Model |
|
CHANACUSTSRC
| Channel A for Custom Interpretation Model Source Tool Path |
|
CHANBCOL
| Optical Density Channel B for Contamination Monitoring Color Model |
|
CHANBCUST
| Channel B for Custom Interpretation Model |
|
CHANBCUSTSRC
| Channel B for Custom Interpretation Model Source Tool Path |
|
CHANSELMODE
| Channel Selection Mode |
|
CMCUSTCNT
| Contamination Monitoring Custom Contamination |
|
CMEXPCUST
| Computation Exponent for Custom Interpretation Model |
|
CMEXPVOL1
| Contamination Monitoring Exponential Volume 1 |
|
CMEXPVOL2
| Contamination Monitoring Exponential Volume 2 |
|
CMFAIL
| Contamination Monitoring Computation Failure Explanation |
|
CMFAILCUST
| Contamination Monitoring Computation Custom Interpretation Failure Explanation |
|
CMREFCOEFCUST
| Reference Coefficient for Custom Interpretation Model |
|
CNTAVG
| Average Percent Contamination of Filtrate |
|
CNTAVG1
| Average Percent Contamination of Filtrate 1 |
|
CNTAVG2
| Average Percent Contamination of Filtrate 2 |
|
CNTCOL
| Percent Contamination of Filtrate (Contamination Monitoring Color Model) |
|
CNTCOL1
| Percent Contamination of Filtrate (Contamination Monitoring Color Model) 1 |
|
CNTCOL2
| Percent Contamination of Filtrate (Contamination Monitoring Color Model) 2 |
|
CNTCUST
| Percent Contamination (Custom Interpretation) |
|
CNTCUST1
| Percent Contamination (Custom Interpretation) 1 |
|
CNTCUST2
| Percent Contamination (Custom Interpretation) 2 |
|
CNTMETH
| Percent Contamination of Filtrate (Contamination Monitoring Methane Model) |
|
CNTMETH1
| Percent Contamination of Filtrate (Contamination Monitoring Methane Model) 1 |
|
CNTMETH2
| Percent Contamination of Filtrate (Contamination Monitoring Methane Model) 2 |
|
DCNSTCOL
| Curve Fitting Constant D for Color |
|
DCNSTCUST
| Curve Fitting Constant D for Custom Interpretaton |
|
DCNSTMETH
| Curve Fitting Constant D for Methane |
|
DDVOLSRC
| Drawdown Volume Source |
|
DIFFCUST
| Difference from Custom Interpretation |
|
DIFFCUST1
| Difference for Custom Interpretation 1 |
|
DIFFCUST2
| Difference for Custom Interpretation 2 |
|
EANLTIM
| End of the Analysis Time |
|
EFITMODE
| End of Fitting Mode |
|
EFITTIM
| End of Fitting Time |
|
EFITTIMCOL
| End of Fitting Time for Contamination Color Model |
|
EFITTIMCUST
| End of Fitting Time for Custom Interpretation Model |
|
EFITTIMMETH
| End of Fitting Time for Contamination Methane Model |
|
EFITVOL
| End of Fitting Volume |
|
EFITVOLCOL
| End of Fitting Volume for Contamination Color Model |
|
EFITVOLCUST
| End of Fitting Volume for Custom Interpretation Model |
|
EFITVOLEXP
| End of Fitting Exponential Volume |
|
EFITVOLEXPCUST
| End of Fitting Exponential Volume Custom Interpretation |
|
EFITVOLMETH
| End of Fitting Volume for Contamination Methane Model |
|
EVALTPMPVOL1
| Evaluation Total Pumped Volume 1 |
|
EVALTPMPVOL2
| Evaluation Total Pumped Volume 2 |
|
EXPVOLCUST1
| Exponential Volume for Custom Interpretation 1 |
|
EXPVOLCUST2
| Exponential Volume for Custom Interpretation 2 |
|
FCOL
| Fluid Coloration |
|
FLORATEAVG
| Flowrate Average |
|
FLVOLCORR
| Flowline Volume Correction |
|
GASD
| Gas Detector Normalized Data |
|
GASI
| Gas Indicator |
|
GOR
| Gas Oil Ratio |
|
GORAVG
| Gas Oil Ratio Average |
|
GORAVGBSMP
| Gas Oil Ratio Average Before Sampling |
|
GORQ
| Gas Oil Ratio Quality Flag |
|
GORQID
| Gas Oil Ratio Quality Flag Image Display |
|
HAFF
| Highly Absorbing Fluid Flag |
|
ICMINTPLT
| Include the Contamination Monitoring Interpretation Plot in Client Product |
|
IEXPPLT
| Include the Exponential Plot in Client Product |
|
ILFADETSUMLIST
| Include This Analysis in the LFA Detailed Summary Listing |
|
ILFASUMLIST
| Include This Analysis in the LFA General Summary Listing |
|
INTID
| Interpretation Identifier |
|
INTSTAID
| Interpretation Station Identifier |
|
IOD3DPLT
| Include the Optical Density 3D Plot in Client Product |
|
IODPLT
| Include the Optical Density Plot in Client Product |
|
ISPECTPLT
| Include the Spectrum Plot in Client Product |
|
LFAID
| LFA Analysis Identifier |
|
LFANUM
| LFA Analysis Number |
|
LFOD
| Live Fluid Spectrometer Optical Density |
|
MDLCUST
| Model from Custom Interpretation |
|
MDLCUST1
| Model for Custom Interpretation 1 |
|
MDLCUST2
| Model for Custom Interpretation 2 |
|
MNPRES
| Minimum Pressure |
|
ODDIFFCOL
| Optical Density Difference for Oil Based Mud Contamination Monitoring Color Model |
|
ODDIFFCOL11
| Optical Density Difference Channel 1 for Contamination Monitoring Color Model 1 |
|
ODDIFFCOL12
| Optical Density Difference Channel 1 for Contamination Monitoring Color Model 2 |
|
ODDIFFCOL21
| Optical Density Difference Channel 2 for Contamination Monitoring Color Model 1 |
|
ODDIFFCOL22
| Optical Density Difference Channel 2 for Contamination Monitoring Color Model 2 |
|
ODDIFFCOL31
| Optical Density Difference Channel 3 for Contamination Monitoring Color Model 1 |
|
ODDIFFCOL32
| Optical Density Difference Channel 3 for Contamination Monitoring Color Model 2 |
|
ODDIFFCOL41
| Optical Density Difference Channel 4 for Contamination Monitoring Color Model 1 |
|
ODDIFFCOL42
| Optical Density Difference Channel 4 for Contamination Monitoring Color Model 2 |
|
ODDIFFCOL51
| Optical Density Difference Channel 5 for Contamination Monitoring Color Model 1 |
|
ODDIFFCOL52
| Optical Density Difference Channel 5 for Contamination Monitoring Color Model 2 |
|
ODDIFFCOL61
| Optical Density Difference Channel 6 for Contamination Monitoring Color Model 1 |
|
ODDIFFCOL62
| Optical Density Difference Channel 6 for Contamination Monitoring Color Model 2 |
|
ODDIFFMETH
| Optical Density Difference for Oil Based Mud Contamination Monitoring Methane Model |
|
ODDIFFMETH1
| Optical Density Difference for Contamination Monitoring Methane Model 1 |
|
ODDIFFMETH2
| Optical Density Difference for Contamination Monitoring Methane Model 2 |
|
ODMDLCOL
| Optical Density Model (Oil Based Mud Contamination Monitoring Color Model) |
|
ODMDLCOL1
| Optical Density Contamination Monitoring Color Model 1 |
|
ODMDLCOL2
| Optical Density Contamination Monitoring Color Model 2 |
|
ODMDLMETH
| Optical Density Model (Oil Based Mud Contamination Monitoring Methane Model) |
|
ODMDLMETH1
| Optical Density Contamination Monitoring Methane Model 1 |
|
ODMDLMETH2
| Optical Density Contamination Monitoring Methane Model 2 |
|
ODSC
| Optical Density Scattering Component |
|
OILF
| Oil Fraction |
|
OILFAVG
| Oil Fraction Average |
|
OILFBSMP
| Oil Fraction Average Before Sampling |
|
PRAVGATSRC
| Pressure Average at Analysis Source |
|
PRAVGATSRCBSMP
| Pressure Average at Analysis Source Before Sampling |
|
RMOD
| Ratio of Methane Optical Density to Oil Optical Density |
|
SANLTIM
| Start of the Analysis Time |
|
SETID
| Set-Retract Sequence Identifier |
|
SFITMODE
| Start of Fitting Mode |
|
SFITTIM
| Start of Fitting Time |
|
SFITTIMCOL
| Start of Fitting Time for Contamination Color Model |
|
SFITTIMCUST
| Start of Fitting Time for Custom Interpretation Model |
|
SFITTIMMETH
| Start of Fitting Time for Contamination Methane Model |
|
SFITVOL
| Start of Fitting Volume |
|
SFITVOLCOL
| Start of Fitting Volume for Contamination Color Model |
|
SFITVOLCUST
| Start of Fitting Volume for Custom Interpretation Model |
|
SFITVOLEXP
| Start of Fitting Exponential Volume |
|
SFITVOLEXPCUST
| Start of Fitting Exponential Volume for Custom Interpretation |
|
SFITVOLMETH
| Start of Fitting Volume for Contamination Methane Model |
|
SPECTCAPTTIM
| Spectrum Capture Time |
|
SPECTCAPTVOL
| Spectrum Capture Volume |
|
SPMPTIM
| Start of Pumping Time |
|
TEMPAVG
| Temperature Average |
|
TGTCNTMLVL
| Target Contamination Level |
|
TIMTOTGTCNTM
| Time Required to Reach Target Contamination Level at Last Pumping Rate |
|
TIMTOTGTCUST
| Time Required to Reach Target Contamination Level at Last Pumping Rate for Custom Interpretation |
|
TOOLPATH
| Tool Path |
|
TPMPVOL
| Total Pump Output Volume |
|
VFID
| Volume Fraction Image Display |
|
VOLPMP
| Volume Pumped |
|
VOLPMPBANL
| Volume Pumped Before Analysis |
|
VOLTOTGT
| Volume required to reach Target Contamination Level |
|
VOLTOTGTCUST
| Volume required to reach Target Contamination Level for Custom Interpretation |
|
WATF
| Water Fraction |
|
WATFAVG
| Water Fraction Average |
|
WATFAVGBSMP
| Water Fraction Average Before Sampling |