Parameter | Description |
ACCU_STCU_DATA_AVG
| Data Average in Accumulation Custom Statistic |
ACCU_STCU_NBR_SAMPLE
| Number Of Samples in Accumulation Custom Statistic |
ACCU_STCU_TCOD_MAX
| Maximal Temperature in Accumulation Custom Statistic |
ACCU_STCU_TCOD_MIN
| Minimal Temperature in Accumulation Custom Statistic |
ACQ_MODE
| Data Acquisition Mode |
AZI_SELECT
| Azimuth Channel Selection |
BAD_FINGERS
| Bad Fingers Ignored for Processing |
BF
| Bad Finger List |
CALIPER_RING1
| Calibration Ring 1 Diameter |
CALIPER_RING10
| Calibration Ring 10 Diameter |
CALIPER_RING2
| Calibration Ring 2 Diameter |
CALIPER_RING3
| Calibration Ring 3 Diameter |
CALIPER_RING4
| Calibration Ring 4 Diameter |
CALIPER_RING5
| Calibration Ring 5 Diameter |
CALIPER_RING6
| Calibration Ring 6 Diameter |
CALIPER_RING7
| Calibration Ring 7 Diameter |
CALIPER_RING8
| Calibration Ring 8 Diameter |
CALIPER_RING9
| Calibration Ring 9 Diameter |
CALIPER_RNG10A
| After Calibration Ring 10 Diameter |
CALIPER_RNG10B
| Before Calibration Ring 10 Diameter |
CALIPER_RNG1A
| After Calibration Ring 1 Diameter |
CALIPER_RNG1B
| Before Calibration Ring 1 Diameter |
CALIPER_RNG2A
| After Calibration Ring 2 Diameter |
CALIPER_RNG2B
| Before Calibration Ring 2 Diameter |
CALIPER_RNG3A
| After Calibration Ring 3 Diameter |
CALIPER_RNG3B
| Before Calibration Ring 3 Diameter |
CALIPER_RNG4A
| After Calibration Ring 4 Diameter |
CALIPER_RNG4B
| Before Calibration Ring 4 Diameter |
CALIPER_RNG5A
| After Calibration Ring 5 Diameter |
CALIPER_RNG5B
| Before Calibration Ring 5 Diameter |
CALIPER_RNG6A
| After Calibration Ring 6 Diameter |
CALIPER_RNG6B
| Before Calibration Ring 6 Diameter |
CALIPER_RNG7A
| After Calibration Ring 7 Diameter |
CALIPER_RNG7B
| Before Calibration Ring 7 Diameter |
CALIPER_RNG8A
| After Calibration Ring 8 Diameter |
CALIPER_RNG8B
| Before Calibration Ring 8 Diameter |
CALIPER_RNG9A
| After Calibration Ring 9 Diameter |
CALIPER_RNG9B
| Before Calibration Ring 9 Diameter |
CFLI
| Check for Finger Limiting |
CYL_LENG
| Cylinder Length |
EXCO
| Eccentering Correction |
EXTFING
| Extended Fingers |
EXTSONDE
| Extended Sonde |
FFCO
| Fully-Opened Fingers Correction |
FING_ECCE_EXCL
| List of Fingers to be excluded from Eccentralization Correction (in Before Calibration) |
FINGER_LST_BAD
| Before Calibration Bad Fingers List |
FINGERS_STATUS
| Before Calibration Good and Bad Fingers |
FINGS_ECC_EXCL
| Finger Exclusion Flag for Eccentralization Correction (in Before Calibration) |
FOCO
| Finger Offset Correction |
FOFF_VAL
| Finger Offset Values |
FWCO
| Finger Wear Correction |
HACC
| Histogram Accumulation Flag |
IFIL
| Inclinometry Filtering |
IGNORE_TCOD_10
| List of TCODs to exclude from Ring Accumulation 10 - Master Calibration |
IGNORE_TCOD_R1
| List of TCODs to exclude from Ring Accumulation 1 - Master Calibration |
IGNORE_TCOD_R2
| List of TCODs to exclude from Ring Accumulation 2 - Master Calibration |
IGNORE_TCOD_R3
| List of TCODs to exclude from Ring Accumulation 3 - Master Calibration |
IGNORE_TCOD_R4
| List of TCODs to exclude from Ring Accumulation 4 - Master Calibration |
IGNORE_TCOD_R5
| List of TCODs to exclude from Ring Accumulation 5 - Master Calibration |
IGNORE_TCOD_R6
| List of TCODs to exclude from Ring Accumulation 6 - Master Calibration |
IGNORE_TCOD_R7
| List of TCODs to exclude from Ring Accumulation 7 - Master Calibration |
IGNORE_TCOD_R8
| List of TCODs to exclude from Ring Accumulation 8 - Master Calibration |
IGNORE_TCOD_R9
| List of TCODs to exclude from Ring Accumulation 9 - Master Calibration |
INCL_EPSILON_MASTER
| Inclinometer Relative Bearing Offset |
INCL_K_MASTER
| Inclinometer Deviation Factor |
INCL_R_MASTER
| X Sensitivity / Y Sensitivity |
INCL_X0_MASTER
| Inclinometer X when Vertical |
INCL_Y0_MASTER
| Inclinometer Y when Vertical |
INCX_0DEG_ACCUM
| Inclinometer INCX 0 Degree Accumulation |
INCX_180DEG_ACCUM
| Inclinometer INCX 180 Degree Accumulation |
INCX_270DEG_ACCUM
| Inclinometer INCX 270 Degree Accumulation |
INCX_90DEG_ACCUM
| Inclinometer INCX 90 Degree Accumulation |
INCX_VERT_ACCUM
| Inclinometer INCX Vertical Accumulation |
INCY_0DEG_ACCUM
| Inclinometer INCY 0 Degree Accumulation |
INCY_180DEG_ACCUM
| Inclinometer INCY 180 Degree Accumulation |
INCY_270DEG_ACCUM
| Inclinometer INCY 270 Degree Accumulation |
INCY_90DEG_ACCUM
| Inclinometer INCY 90 Degree Accumulation |
INCY_VERT_ACCUM
| Inclinometer INCY Vertical Accumulation |
LQC_RADII_RESIDUALS
| Fingers Wellsite Calibration Radius Residuals |
MCAL_INCL_TDEV
| Tool Deviation During Inclinometry Calibration |
MEAS_TRAD_RING1
| Fingers Wellsite Measured TRAD Ring 1 |
MEAS_TRAD_RING10
| Fingers Wellsite Measured TRAD Ring 10 |
MEAS_TRAD_RING2
| Fingers Wellsite Measured TRAD Ring 2 |
MEAS_TRAD_RING3
| Fingers Wellsite Measured TRAD Ring 3 |
MEAS_TRAD_RING4
| Fingers Wellsite Measured TRAD Ring 4 |
MEAS_TRAD_RING5
| Fingers Wellsite Measured TRAD Ring 5 |
MEAS_TRAD_RING6
| Fingers Wellsite Measured TRAD Ring 6 |
MEAS_TRAD_RING7
| Fingers Wellsite Measured TRAD Ring 7 |
MEAS_TRAD_RING8
| Fingers Wellsite Measured TRAD Ring 8 |
MEAS_TRAD_RING9
| Fingers Wellsite Measured TRAD Ring 9 |
MIT_RING1_DIA
| PMIT Master Calibration Ring 1 diameter |
MIT_RING2_DIA
| PMIT Master Calibration Ring 2 diameter |
MIT_RING3_DIA
| PMIT Master Calibration Ring 3 diameter |
MIT_RING4_DIA
| PMIT Master Calibration Ring 4 diameter |
MIT_RING5_DIA
| PMIT Master Calibration Ring 5 diameter |
MIT_RING6_DIA
| PMIT Master Calibration Ring 6 diameter |
MIT_RING7_DIA
| PMIT Master Calibration Ring 7 Diameter |
MIT_RING8_DIA
| PMIT Master Calibration Ring 8 Diameter |
MIT_SONDEX_SN
| PMIT Sondex Serial Number |
OVCO
| Ovalization Correction |
PFBOD
| Future Cylinder Outside Diameter |
PMIT_CAL_DATE
| Calibration Date |
PMIT_CAL_FING_COUNT
| Number of fingers |
PMIT_CALI_MAX
| PMIT Caliper Max Opening |
PMIT_CALI_MIN
| PMIT Caliper Min Opening |
PMIT_CSF
| Finger Scale Factor |
PMIT_CUF
| Master Calibration Units Factor |
PMIT_EPSILON_MASTER
| RB offset |
PMIT_FINGERS
| PMIT Number of Fingers |
PMIT_K_MASTER
| Deviation factor |
PMIT_MAX_CALIPER
| Max Calibrated Caliper |
PMIT_MAX_TEMP
| Max Calibrated Temperature |
PMIT_MIN_CALIPER
| Min Calibrated Caliper |
PMIT_MIN_TEMP
| Min Calibrated Temperature |
PMIT_R_MASTER
| X sensitivity / Y sensitivity |
PMIT_RADII_AFT_GAIN
| Radii Gain after stage |
PMIT_RADII_AFT_OFFS
| Radii Offset after stage |
PMIT_RADII_BEF_GAIN
| Radii Gain before stage |
PMIT_RADII_BEF_OFFS
| Radii Offset before stage |
PMIT_SERIAL_NUMBER
| Serial Number |
PMIT_SONDEX_SN
| PMIT Sondex Serial Number |
PMIT_T0
| Lowest raw temperature reading noted during the mastercal |
PMIT_TCOR_ARM0
| RM0 Temperature Correction Coefficient |
PMIT_TCOR_G0
| GO Temperature Correction Coefficient |
PMIT_TCOR_G1
| G1 Temperature Correction Coefficient |
PMIT_TCOR_G2
| G2 Temperature Correction Coefficient |
PMIT_TCOR_G3
| G3 Temperature Correction Coefficient |
PMIT_TCOR_H0
| H0 Temperature Correction Coefficient |
PMIT_TCOR_H1
| H1 Temperature Correction Coefficient |
PMIT_TCOR_H2
| H2 Temperature Correction Coefficient |
PMIT_TCOR_H3
| H3 Temperature Correction Coefficient |
PMIT_TCOR_I0
| I0 Temperature Correction Coefficient |
PMIT_TCOR_I1
| I1 Temperature Correction Coefficient |
PMIT_TCOR_I2
| I2 Temperature Correction Coefficient |
PMIT_TCOR_I3
| I3 Temperature Correction Coefficient |
PMIT_TCOR_J0
| J0 Temperature Correction Coefficient |
PMIT_TCOR_J1
| J1 Temperature Correction Coefficient |
PMIT_TCOR_J2
| J2 Temperature Correction Coefficient |
PMIT_TCOR_J3
| J3 Temperature Correction Coefficient |
PMIT_TCOR_RESIDUAL
| RESIDUAL Temperature Correction Coefficient |
PMIT_TSF
| Temperature Scale Factor |
PMIT_VRES
| PMIT Vertical Resolution |
PMIT_X0_MASTER
| Inclinometer X when vertical |
PMIT_Y0_MASTER
| Inclinometer Y when vertical |
RADII_BAD_FINGERS
| List of Before and After Calibration Bad Fingers |
RADII_CAL_DATE
| RADII Master Calibration Date |
RADII_CAL_FING_NBR
| RADII Sonde Number Of Fingers |
RADII_CSF
| Finger Scale Factor |
RADII_CUF
| Master Calibration Units Factor |
RADII_GAIN
| Gain Factor for the Before Fingers Measurements |
RADII_MAX_CALIPER
| Maximum Calibration Diameter |
RADII_MAX_TCOD
| Maximum Calibration Temperature Telemetry Word |
RADII_MAX_TEMP
| Maximum Calibration Temperature |
RADII_MIN_CALIPER
| Minimum Calibration Diameter |
RADII_MIN_TCOD
| Minimum Calibration Temperature Telemetry Word |
RADII_MIN_TEMP
| Minimum Calibration Temperature |
RADII_OFFSET
| Offset for the Before Fingers Measurements |
RADII_SONDE_SN
| RADII Sonde Serial Number |
RADII_SONDEX_SN
| Sonde Sondex Serial Number |
RADII_T0
| Lowest Raw Temperature Reading Noted During Master Calibration |
RADII_TCOR_ARM0
| Lowest Raw Arm Reading at Minimum Ring Size |
RADII_TCOR_G0
| GO Temperature Correction Coefficient |
RADII_TCOR_G1
| G1 Temperature Correction Coefficient |
RADII_TCOR_G2
| G2 Temperature Correction Coefficient |
RADII_TCOR_G3
| G3 Temperature Correction Coefficient |
RADII_TCOR_H0
| H0 Temperature Correction Coefficient |
RADII_TCOR_H1
| H1 Temperature Correction Coefficient |
RADII_TCOR_H2
| H2 Temperature Correction Coefficient |
RADII_TCOR_H3
| H3 Temperature Correction Coefficient |
RADII_TCOR_I0
| I0 Temperature Correction Coefficient |
RADII_TCOR_I1
| I1 Temperature Correction Coefficient |
RADII_TCOR_I2
| I2 Temperature Correction Coefficient |
RADII_TCOR_I3
| I3 Temperature Correction Coefficient |
RADII_TCOR_J0
| J0 Temperature Correction Coefficient |
RADII_TCOR_J1
| J1 Temperature Correction Coefficient |
RADII_TCOR_J2
| J2 Temperature Correction Coefficient |
RADII_TCOR_J3
| J3 Temperature Correction Coefficient |
RADII_TCOR_RESIDUAL
| Fingers Master Calibration Radius Residuals |
RADII_TSF
| Temperature Scale Factor |
RING1_MCAL_ACCUM
| Calibration Ring 1 Master Cal Accumulation |
RING1_RAW_ACCUM
| Calibration Ring 1 Raw Finger Accumulation |
RING1_TCOD_ACCUM
| Calibration Ring 1 TCOD Accumulation |
RING10_MCAL_ACCUM
| Calibration Ring 10 Master Cal Accumulation |
RING10_RAW_ACCUM
| Calibration Ring 10 Raw Finger Accumulation |
RING10_TCOD_ACCUM
| Calibration Ring 10 TCOD Accumulation |
RING2_MCAL_ACCUM
| Calibration Ring 2 Master Cal Accumulation |
RING2_RAW_ACCUM
| Calibration Ring 2 Raw Finger Accumulation |
RING2_TCOD_ACCUM
| Calibration Ring 2 TCOD Accumulation |
RING3_MCAL_ACCUM
| Calibration Ring 3 Master Cal Accumulation |
RING3_RAW_ACCUM
| Calibration Ring 3 Raw Finger Accumulation |
RING3_TCOD_ACCUM
| Calibration Ring 3 TCOD Accumulation |
RING4_MCAL_ACCUM
| Calibration Ring 4 Master Cal Accumulation |
RING4_RAW_ACCUM
| Calibration Ring 4 Raw Finger Accumulation |
RING4_TCOD_ACCUM
| Calibration Ring 4 TCOD Accumulation |
RING5_MCAL_ACCUM
| Calibration Ring 5 Master Cal Accumulation |
RING5_RAW_ACCUM
| Calibration Ring 5 Raw Finger Accumulation |
RING5_TCOD_ACCUM
| Calibration Ring 5 TCOD Accumulation |
RING6_MCAL_ACCUM
| Calibration Ring 6 Master Cal Accumulation |
RING6_RAW_ACCUM
| Calibration Ring 6 Raw Finger Accumulation |
RING6_TCOD_ACCUM
| Calibration Ring 6 TCOD Accumulation |
RING7_MCAL_ACCUM
| Calibration Ring 7 Master Cal Accumulation |
RING7_RAW_ACCUM
| Calibration Ring 7 Raw Finger Accumulation |
RING7_TCOD_ACCUM
| Calibration Ring 7 TCOD Accumulation |
RING8_MCAL_ACCUM
| Calibration Ring 8 Master Cal Accumulation |
RING8_RAW_ACCUM
| Calibration Ring 8 Raw Finger Accumulation |
RING8_TCOD_ACCUM
| Calibration Ring 8 TCOD Accumulation |
RING9_MCAL_ACCUM
| Calibration Ring 9 Master Cal Accumulation |
RING9_RAW_ACCUM
| Calibration Ring 9 Raw Finger Accumulation |
RING9_TCOD_ACCUM
| Calibration Ring 9 TCOD Accumulation |
SDEV
| Tool deviation during inclinometry calibration |
TORTUOSITY_CMP
| Tortuosity Computation |
USE_FOR_OFFSET
| Use For Default Offset Computation |
VRES
| Vertical Resolution |
WEAR
| Finger Wear Values |
WEAR_VAL
| Finger Wear Values |
WLI
| Logged Interval (for wear correction) |