| Parameter | Description |
|
A1T1B
| BS 75/25 Stabilization Counts Temperature Correction Coefficients |
|
A1T1L
| LS 75/25 Stabilization Counts Temperature Correction Coefficients |
|
A1T1S
| SS 75/25 Stabilization Counts Temperature Correction Coefficients |
|
A1T2B
| BS 125/25 Stabilization Counts Temperature Correction Coefficients |
|
A1T2L
| LS 125/25 Stabilization Counts Temperature Correction Coefficients |
|
A1T2S
| SS 125/25 Stabilization Counts Temperature Correction Coefficients |
|
A1T3B
| BS 150/25 Stabilization Counts Temperature Correction Coefficients |
|
A1T3L
| LS 150/25 Stabilization Counts Temperature Correction Coefficients |
|
A1T3S
| SS 150/25 Stabilization Counts Temperature Correction Coefficients |
|
BCQR_MAS_STA
| Average of BCQR During Shop Background |
|
BCQR_VAR
| BS Crystal Quality Resolution Variation (History Check) |
|
BPHV_VAR
| BS Photomultiplier High Voltage Variation (History Check) |
|
BS_ALURATIO_COMPUTED
| SS Computed Window Aluminum Ratio |
|
BS_AVEDEV_COMPUTED
| BS Computed Average Deviation |
|
BS_MAXDEV_COMPUTED
| BS Computed Maximum Deviation |
|
BS_WRAT_BEF_COMPUTED
| BS Before Computed Window Ratio |
|
BS_WRAT_COMPUTED
| BS Computed Window Ratio |
|
BS_WSUM_BEF_COMPUTED
| BS Before Computed Window Sum |
|
BS_WSUM_COMPUTED
| BS Computed Window Sum |
|
BSD1_MAS_STA
| Average of BSD1 During Shop Background |
|
BSW_GAIN
| Calibration Gain Applied to the Measured BSW |
|
BSW_OFFSET
| Calibration Offset Applied to the Measured BSW |
|
BSWT_DEV_AVG
| BS Average Count Rate Deviation (History Check) |
|
BSWT_DEVM_AFE
| BS Aluminum+Sleeve Count Rate Deviation (History Check) |
|
BSWT_DEVM_ALU
| BS Aluminum Count Rate Deviation (History Check) |
|
BSWT_DEVM_MAG
| BS Magnesium Count Rate Deviation (History Check) |
|
BSWT_DEVM_MFE
| BS Magnesium+Sleeve Count Rate Deviation (History Check) |
|
BSWU_MAS_STA
| Average of BSWU During Shop Background |
|
CAL_LHK
| Caliper Large Hole Kit |
|
CALI_LIN_OFFSET
| Caliper Linear Offset |
|
CALIPER_GAIN
| Gain factor for the caliper measurement |
|
CALIPER_OFFSET
| Offset for the caliper measurement |
|
CALIPER_PLUS_ACCUM
| Average of Caliper During Plus Accumulation |
|
CALIPER_ZERO_ACCUM
| Average of Caliper During Zero Accumulation |
|
DHC
| Density Hole Correction |
|
GAMMA_SRC_ACTIVITY
| Gamma Source Activity (History Check) |
|
GCLF
| Coal-Like Formation |
|
HRGD_BRD_TYPE
| HRGD Board Type |
|
HSSO
| Weak Source |
|
LARGE_RING
| Caliper Calibration Large Ring |
|
LCQR_MAS_STA
| Average of LCQR During Shop Background |
|
LCQR_VAR
| LS Crystal Quality Resolution Variation (History Check) |
|
LHEW_MAS_STA
| Average of LHEW During Shop Background |
|
LPHV_VAR
| LS Photomultiplier High Voltage Variation (History Check) |
|
LS_ALURATIO_COMPUTED
| LS Computed Window Aluminum Ratio |
|
LS_AVEDEV_COMPUTED
| LS Computed Average Deviation |
|
LS_MAXDEV_COMPUTED
| LS Computed Maximum Deviation |
|
LS_WRAT_BEF_COMPUTED
| LS Before Computed Window Ratio |
|
LS_WRAT_COMPUTED
| LS Computed Window Ratio |
|
LS_WSUM_BEF_COMPUTED
| LS Before Computed Window Sum |
|
LS_WSUM_COMPUTED
| LS Computed Window Sum |
|
LSD1_MAS_STA
| Average of LSD1 During Shop Background |
|
LSW_GAIN
| Calibration Gain Applied to the Measured LSW |
|
LSW_OFFSET
| Calibration Offset Applied to the Measured LSW |
|
LSWT_DEV_AVG
| LS Average Count Rate Deviation (History Check) |
|
LSWT_DEVM_AFE
| LS Aluminum+Sleeve Count Rate Deviation (History Check) |
|
LSWT_DEVM_ALU
| LS Aluminum Count Rate Deviation (History Check) |
|
LSWT_DEVM_MAG
| LS Magnesium Count Rate Deviation (History Check) |
|
LSWT_DEVM_MFE
| LS Magnesium+Sleeve Count Rate Deviation (History Check) |
|
LSWU_MAS_STA
| Average of LSWU During Shop Background |
|
M_QUAL_COMPUTED
| Calibration Quality Flag |
|
M_SOURCE_COMPUTED
| Source Quality Flag |
|
MHCC
| Switch to select MCFL High Contrast Correction |
|
MPOF
| MCFL Processing Operation Mode |
|
NAAC
| Switch for the correction of formation activation by the APS |
|
NACO
| Neutron Activation Correction |
|
NDTC
| Nuclear Dead Time Correction |
|
NPRM
| HRDD Nuclear Processing Mode |
|
NPUC
| Nuclear Pile-Up Correction |
|
NTCO
| HRDD Nuclear Temperature Correction Option |
|
PE_ALU_COMPUTED
| Computed Pe in Aluminum |
|
PE_FILTER
| Photoelectric Factor Filter |
|
PE_MAG_COMPUTED
| Computed Pe in Magnesium |
|
RHET_MAS_STA
| Average of RHET During Shop Background |
|
RHO_ALU_COMPUTED
| Computed Rho in Aluminum |
|
RHO_MAG_COMPUTED
| Computed Rho in Magnesium |
|
RVDR_GAIN
| Calibration Gain Applied to the Measured RVDR |
|
RVSR_GAIN
| Calibration Gain Applied to the Measured RVSR |
|
RXR_GAIN
| Calibration Gain Applied to the Measured RXR |
|
SCQR_MAS_STA
| Average of SCQR During Shop Background |
|
SCQR_VAR
| SS Crystal Quality Resolution Variation (History Check) |
|
SD1B
| BS Pulse Processing Filter Temperature Coefficient |
|
SD1L
| LS Pulse Processing Filter Temperature Coefficient |
|
SD1S
| SS Pulse Processing Filter Temperature Coefficient |
|
SMALL_RING
| Caliper Calibration Small Ring |
|
SPHV_VAR
| SS Photomultiplier High Voltage Variation (History Check) |
|
SS_ALURATIO_COMPUTED
| BS Computed Window Aluminum Ratio |
|
SS_AVEDEV_COMPUTED
| SS Computed Average Deviation |
|
SS_MAXDEV_COMPUTED
| SS Computed Maximum Deviation |
|
SS_WRAT_BEF_COMPUTED
| SS Before Computed Window Ratio |
|
SS_WRAT_COMPUTED
| SS Computed Window Ratio |
|
SS_WSUM_BEF_COMPUTED
| SS Before Computed Window Sum |
|
SS_WSUM_COMPUTED
| SS Computed Window Sum |
|
SSD1_MAS_STA
| Average of SSD1 During Shop Background |
|
SSHB
| BS Barium Measurement High Energy Temperature Shift |
|
SSHL
| LS Barium Measurement High Energy Temperature Shift |
|
SSHS
| SS Barium Measurement High Energy Temperature Shift |
|
SSLB
| BS Barium Measurement Low Energy Temperature Shift |
|
SSLL
| LS Barium Measurement Low Energy Temperature Shift |
|
SSLS
| SS Barium Measurement Low Energy Temperature Shift |
|
SSW_GAIN
| Calibration Gain Applied to the Measured SSW |
|
SSW_OFFSET
| Calibration Offset Applied to the Measured SSW |
|
SSWT_DEV_AVG
| SS Average Count Rate Deviation (History Check) |
|
SSWT_DEVM_AFE
| SS Aluminum+Sleeve Count Rate Deviation (History Check) |
|
SSWT_DEVM_ALU
| SS Aluminum Count Rate Deviation (History Check) |
|
SSWT_DEVM_MAG
| SS Magnesium Count Rate Deviation (History Check) |
|
SSWT_DEVM_MFE
| SS Magnesium+Sleeve Count Rate Deviation (History Check) |
|
SSWU_MAS_STA
| Average of SSWU During Shop Background |
|
STSO_HRDD
| Temperature Source for the Density Algorithm |
|
TA1B
| BS Stabilization Counts Measurement Temperature |
|
TA1L
| LS Stabilization Counts Measurement Temperature |
|
TA1S
| SS Stabilization Counts Measurement Temperature |
|
TSHB
| BS Barium Measurement Temperature |
|
TSHL
| LS Barium Measurement Temperature |
|
TSHS
| SS Barium Measurement Temperature |